CJ-series CompoNet Master Units CJ1W-CRM21

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.
NameAppear- 
ance
SpecificationsNumber 
of unit 
numbers 
allocated
Power 
consumption (A)
ModelStand- 
ards
Type of 
communi- 
cations
Maximum number 
of I/O points per 
Master Unit
5-V 
system
24-V 
system
CJ1 
Special 
I/O Unit
1779_lu_1_1Remote I/O 
communica- 
tions 
Message 
communica- 
tions
Word Slave Units: 
1,024 inputs and 1,024 
outputs (2,048 I/O 
points total) 
Bit Slave Units: 256 
inputs and 256 outputs 
(512 I/O points total)
1, 2, 4, 
or 8
0.4-CJ1W-CRM21CE, U, 
U1, L, 
N
Note: Observe the following precautions if you use the CompoNet Master Unit in an NJ-series Machine Automation 
          Controller. 
           • Supported only by the CPU Units with unit version 1.01 or later and the Sysmac Studio version 1.02 or higher. 
           • You cannot use the simple backup function. 
           • You cannot send FINS commands to the CompoNet Master Unit.

Software

How to Select Required Support Software for Your Controller

The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.
ItemOmron PLC SystemOmron Machine Automation Controller System
ControllerCS,CJ,CP,and other seriesNJ-series
SoftwareFA Integrated Tool Package CX-OneAutomation Software Sysmac Studio

FA Integrated Tool Package CX-One

Product 
name
SpecificationsModelStand- 
ards
Number of 
licenses
Media
FA 
Integrated 
Tool 
Package 
CX-One 
Ver.4.[]
The CX-One is a comprehensive software package 
that integrates Support Software for OMRON PLCs 
and components. 

CX-One runs on the following OS. 
OS:Windows XP (Service Pack 3 or higher, 32-bit 
version)/Windows Vista (32-bit/64-bit version)/ 
Windows 7 (32-bit/64-bit version)/Windows 8 (32-bit/ 
64-bit version)/Windows 8.1 (32-bit/64-bit version) / 
Windows 10 (32-bit/64-bit version) 

CX-One Version 4.[] includes CX-Integrator Ver.3.[]. 
For details, refer to the CX-One catalog (Cat. No. 
R134)
1 license 
*
DVDCXONE-AL01D-V4-
* Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.

Automation Software Sysmac Studio

Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
Product 
name
SpecificationsModelStand- 
ards
Number of 
licenses
Media
Sysmac 
Studio 
Standard
Edition 
Ver.1.[][]
The Sysmac Studio provides an integrated development 
environment to set up, program, debug, and maintain 
NJ-series Controllers and other Machine Automation 
Controllers, as well as EtherCAT slaves. 

Sysmac Studio runs on the following OS. 
OS: 
Windows XP (Service Pack 3 or higher, 32-bitversion) / 
Windows Vista (32-bit version) / 
Windows 7 (32-bit/64-bit version) / 
Windows 8 (32-bit/64-bit version) / 
Windows 8.1 (32-bit/64-bitversion) / 
Windows 10 (32-bit/64-bit version) 

The Sysmac Studio Standard Edition DVD includes 
Support Software to set up EtherNet/IP Units, DeviceNet
slaves, Serial Communications Units, and Support 
Software for creating screens on HMIs (CX-Designer). 
For details, refer to the Sysmac Integrated Catalogue 
(P072).

(Media only)
DVDSYSMAC-SE200D-
1 license 
*
-SYSMAC-SE201L-
* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).

Communication Specifications

ItemSpecification
Communications protocolCompoNet Network protocol
Types of communicationsRemote I/O communications (programless,constant sharing of data with Slave Units)and message 
communications (explicit message communications as required with Slave Units and FINS message 
communications as required with Controllers *1)
Baud rate4 Mbps *2,3 Mbps,1.5 Mbps,93.75 kbps
ModulationBase-band
CodingManchester code
Error controlManchester code rules,CRC
Communications mediaThe following media can be used.*
Round cable I (JIS C 3306,2-conductor 0.75 mm2) 
Round cable II (JIS C3306 4-conductor 0.75 mm2) 
Flat Cable I (DCA4-4F10 Standard Flat Cable) 
Flat Cable II (DCA5-4F10 Sheathed Flat Cable)
Communications distance 
and wiring
Refer to Cable Types,Baud Rates,and Maximum Distances.
Connectable Master UnitsCompoNet Master Units
Connectable Slave UnitsCompoNet Slave Units
Maximum I/O capacityWord Slave Units:1,024 inputs and 1,024 outputs (2,048 I/O points total) 
Bit Slave Units:256 inputs and 256 outputs (512 I/O points total)
Maximum number of nodesWord Slave Units:64 input nodes and 64 output nodes 
Bit Slave Units:128 input nodes and 128 output nodes 
Repeater Units:64 nodes
Bits allocated per node 
address
Word Slave Units:16 bits 
Bit Slave Units:2 bits
Maximum number of nodes 
per trunk line or sub-trunk 
line
32 nodes (including Repeater Units)
Applicable node addressesWord Slave Units:IN0 to IN63 and OUT0 to OUT63 
Bit Slave Units:IN0 to IN127 and OUT0 to OUT127 
Repeater Units:0 to 63
Repeater Unit application 
conditions
Up to 64 Repeater Units can be connected per network.When Repeater Units are connected in series 
from the Master Unit,up to 2 extra segment layers can be created (i.e.,up to 2 Repeater Units are 
allowed between a Slave Unit and the Master Unit).
Signal linesTwo lines:BDH (communications data high)and BDL (communications data low)
Power linesTwo lines:BS+and BS -(power for communications and internal Slave Unit circuits) 
Power is supplied from the Master Unit or Repeater Units.
Communications power 
supply
24 VDC ± 10%
Connection formsFlat Cable at baud rate of 93.75 kbps:No restrictions 
Other cables or baud rates:Trunk line and branch lines
Connections for Slave Units and Repeater Units:T-branch or multidrop connections
*1. FINS message communications are supported by CJ-series Controllers only. 
*2. Drop-line connections are not supported with a baud rate of 4 Mbps, so Slaves with prewired cables (Bit Slaves) 
       cannot be used. 
*3. Round cable, Flat Cable, and Flat Cable II are all different types of cable. To use more than one type of cable at a 
        time, Repeater Units must be used to separate them on trunk lines and sub-trunk lines.

Cable Types, Baud Rates, and Maximum Distances

This section provides specifications on the maximum cable length and maximum number of nodes for each type of cable. Do not exceed these specifications.
CJ1W-CRM21 Specifications 3

Restrictions (at Baud Rate of 4 Mbps (No Branch Lines))

Cable typeMaximum length per segment 
(maximum length with 
Repeater Units)
Branch
line 
length
Total branch 
line length 
per segment
Branch 
location 
restrictions
Maximum number of 
Slave Units per 
segment *2
Round cable I30 m (90 m)0 m *10 m *1-32 nodes
Flat Cable I and Flat Cable II 
Round Cable II
30 m (90 m)0 m *10 m *1-32 nodes
*1. T-branches cannot be connected (only multidrop connections are possible). 
*2. Number of nodes including Repeater Units

Restrictions (at Baud Rate of 3 Mbps)

Cable typeMaximum length 
per segment 
(maximum 
length with 
Repeater Units)
Branch
line 
length
Total 
branch line 
length per 
segment
Branch 
location 
restrictions
Maximum
number of 
nodes per 
branch *1
Sub- 
branch
line 
length
Total sub- 
branch line 
length per 
segment
Maximum 
number 
of Slave 
Units per 
segment *2
Round cable I30 m (90 m)0.5 m8 m3 branches/m1 node0 m0 m32 nodes
Flat Cable I 
and Flat Cable II 
Round Cable II
30 m (90 m)0.5 m8 m3 branches/m1 node0 m0 m32 nodes
*1. The maximum number of nodes per branch is the maximum number of Slave Units or Repeater Units that can be 
       connected to one branch line using multidrop or T-branch connections (sub-branches). 
*2. Number of nodes including Repeater Units

Restrictions (at Baud Rate of 1.5 Mbps)

Cable typeMaximum length 
per segment 
(maximum 
length with 
Repeater Units)
Branch
line 
length
Total 
branch line 
length per
segment
Branch 
location 
restrictions
Maximum
number of 
nodes per 
branch *1
Sub- 
branch
line 
length
Total sub-
branch line 
length per
segment
Maximum
number 
of Slave 
Units per 
segment *2
Round
cable I
Without 
branches
100 m (300 m)0 m *30 m *3----32 nodes
With 
branches
30 m (90 m)2.5 m25 m3 branches/m3 nodes0 m0 m32 nodes
Flat Cable I and 
Flat Cable II 
Round Cable II
30 m (90 m)2.5 m25 m3 branches/m3 nodes0.1 m *42 m *432 nodes
*1. The maximum number of nodes per branch is the maximum number of Slave Units or Repeater Units that can be 
       connected to one branch line using multidrop or T-branch connections (sub-branches). 
*2. Number of nodes including Repeater Units 
*3. T-branches cannot be connected (only multidrop connections are possible). 
*4. T-branch connections from sub-branch lines.

Restrictions (at Baud Rate of 93.75 kbps)

Cable typeMaximum length 
per segment 
(maximum 
length with 
Repeater Units)
Branch
line 
length
Total 
branch line 
length per 
segment
Branch 
location 
restrictions
Maximum
number of 
nodes per 
branch *1
Sub- 
branch
line 
length
Total sub- 
branch line 
length per 
segment
Maximum 
number 
of Slave 
Units per 
segment *2
Round cable I500 m (1500 m)6 m120 m3 branches/m1 node--32 nodes
Flat Cable I 
and Flat Cable II 
Round Cable II
No restrictions to a total length per segment of 200 m32 nodes
*1. The maximum number of nodes per branch is the maximum number of Slave Units or Repeater Units that can be 
       connected to one branch line using multidrop or T-branch connections (sub-branches). 
*2. Number of nodes including Repeater Units

Specifications

ModelCJ1W-CRM21
Applicable ControllersNJ *1 /CJ Series
Unit classificationCJ-series Special I/O Unit
Current consumption (Power
supplied from Power Supply 
Unit)
400 mA max.at 5 VDC
Communications power supply 
connector
One communications power supply connector for Slave Units and Repeater Units on the trunk line 
when using Flat Cable *2
Communications power supply 
connector allowable current 
capacity
5 A max.
Maximum number of mountable 
Master Units
One word number assigned:40 Units 
Two word numbers assigned:40 Units 
Four word numbers assigned:24 Units 
Eight word numbers assigned:12 Units
Mounting locationAccording to NJ/CJ-series Special I/O Unit specifications.
Communications power ON/OFF 
monitoring
The ON/OFF status of the communications power supply can be detected at the communications 
power supply connector.
Data stored in Master Unit 
(built-in EEPROM)
1)The following device parameters: 
Registration Table 
Registration Table Check Type 
Registered Slave Unit Participation Monitoring Time,Registered Slave Unit Participation Standby 
Mode,and Event Disable Setting 
Software Settings Table 
Communications Error Communications Stop Mode 
Communications Error Input Data Zero Clear Mode 
Network settings 
2)Part of error history (depends on type of error; mainly serious error related to communications 
stopping)
Noise immunityConforms to IEC 61000-4-4 2 kV (applied to power supply).
Vibration resistance10 to 61.2 Hz with single-amplitude of 0.1 mm,61.2 to 150 Hz and 14.7 m/s2 in X,Y,and Z
directions for 80 min each (sweep time of 8 min × 10 sweeps =80 min)
Shock resistance196 m/s2 (3 times each in X,Y,and Z directions)
Dielectric strength1,000 VAC for 1 min,Leakage current:1 mA max. 
Between communications connector or external current supply connector and GR terminal on 
Power Supply Unit 
Between communications connector or external current supply connector and all Unit connectors
Insulation resistance20 MΩ min.(between isolated circuits)
Ambient operating temperature0 to 55°C
Ambient operating humidity10 to 90%(no condensation)
Ambient operating atmosphereNo corrosive gases
Storage temperature-20 to 75°C
Weight130 g max.(Master Unit only)
*1. Supported only by the CPU Units with unit version 1.01 or later and the Sysmac Studio version 1.02 or higher. 
*2. The Master Unit does not required communications power.

CJ-series B7A Interface Unit CJ1W-B7A


It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort. This unit is available for CJ/NJ controller.

A CJ1W-B7A unit can transmit 64 points of I/O signals.
The slim body can downsize machines to which CJ1W-B7A is connected.
It is a basic I/O unit. No complicated setting and programs are required.

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.
Unit
type
NameSpecificationsNo. of
words
allocated
Current
consumption (A)
ModelStandards
I/O pointsExternal
connection
5 V24 V
CJ1
Basic
I/O
Units
B7A
Interface
Units
64 inputsRemovable
terminal block
4 words0.07---CJ1W-B7A14UC1, CE
64 outputs0.07---CJ1W-B7A04
32 inputs/
outputs
0.07---CJ1W-B7A22

B7A Communications Specifications

ItemSpecifications
Transmission methodOne-way time-sharing multiplex transmissions
Transmission delay
(communications delay
on transmission path)
High-speed3 ms typical, 5 ms max.
Standard19.2 ms typical, 31 ms max.
Transmission pointsCJ1W-B7A1464 inputs (4 ports)
CJ1W-B7A0464 outputs (4 ports)
CJ1W-B7A2232 inputs (2 ports), 32 outputs (2 ports)
External power supply
voltage *1
12 to 24 V DC (allowable voltage range: 10.8 to 26.4 V)
External supply
current *2
CJ1W-B7A1440 mA min.
CJ1W-B7A04150 mA min.
CJ1W-B7A2280 mA min.
Minimum input time
*3
High-speed16 ms
Standard2.4 ms
Transmission distanceHigh-speedPower supply on one side
(common power supply)
10 m max.
50 m max. (with shielded cable)
Power supply on both sides
(separate power supplies)
10 m max.
100 m max. (with shielded cable)
StandardPower supply on one side
(common power supply)
100 m max.
Power supply on both sides
(separate power supplies)
500 m max.
CablesVCTF, 0.75 mm2, 3 conductors (power supply on one side (common power supply))
VCTF, 0.75 mm2, 2 conductors (power supply on both sides (separate power supplies))
Shielded cable, 0.75 mm2, 3 conductors (power supply on one side (common power supply))
Shielded cable, 0.75 mm2, 2 conductors (power supply on both sides (separate power supplies))
Note: 1. When separate power supplies are used, the B7A Interface Unit and B7A Link Terminal are supplied by separate 
              external power supplies. 
           2. When a common power supply is used, the B7A Interface Unit and B7A Link Terminal are supplied by the same 
                external power supply. 
*1. We recommend OMRON S8[][]-series Power Supply Units for the external power supplies. 
*2. The capacity of the external supply current does not include the capacity required by the B7A Link Terminal. 
*3. The minimum input time is the minimum time required by the B7A Interface Unit to read the input signals from the 
       CPU Unit.

Specifications

ModeStandard modeHigh-speed mode
I/O pointsIN 32/OUT 32 (CJ1W-B7A22)
IN 64 (CJ1W-B7A14)
OUT 64 (CJ1W-B7A04)
Transmission methodOne-way time-sharing multiplex transmissions
Transmission distance500m max.100m max.
Transmission delay19.2ms (typical)3ms (typical)
Minimum input time16ms2.4ms
Power Supply voltage
(allowable voltage range)
12 to 24VDC (10.8 to 26.4VDC)
I/O memory AllocationsEach Unit is allocated 4 words in the I/O Area (which starts at CIO 0000). The words are allocated
according to the mounting position of the Unit.
Transmission error bitA transmission error bit for each input port is allocated in the Basic I/O Unit Information Area.
CableVCTF, 0.75mm2 recommended.

CJ1W-B7A14/04/22

CJ1W-B7A Dimensions 2 CJ1W-B7A14/04/22_Dim

CJ-series Quick-response Input Units CJ1W-IDP01

Capture Input Signals Shorter Than the Cycle Time. This unit is available for CJ/NJ controller.

A pulse width (ON time) of 0.05 ms min. can be read by the Quick-response Input Unit.
Input data read by the internal circuits is cleared when inputs are refreshed.
Quick-response Input Units can be used when communicating with inspection equipment to read the many pulse signals that are too short to be read with normal I/O Units

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

Quick-response Input Unit

Unit type: CJ1 Basic I/O Units
No. of words allocated: 1 word
Standards: UC1, N, L, CE
Product
name
SpecificationsCurrent
consumption (A)
Model
I/O pointsInput voltage
current
CommonsInput pulse width
conditions
External
connection
5 V24 V
Quick-
response
Input Unit
16 inputs24 VDC, 7 mA16 points,
1 common
ON time: 0.05 ms max.
OFF time: 0.5 ms max.
Removable
terminal block
0.08---CJ1W-IDP01
Note: There are no restrictions on the mounting position or number of Units.

Accessories

There is no accessory for the CJ series Quick-response Input Units.

CJ1W-IDP01 Quick-response Input Unit (16 Points)

Name16-point Quick-response Input Unit with Terminal Block
ModelCJ1W-IDP01
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance3.3 kΩ
Input Current7 mA typical (at 24 VDC)
ON Voltage/ON Current14.4 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time0.05 ms max.
OFF Response Time0.5 ms max.
Number of Circuits16 (16 points/common, 1 circuit)
Number of Simultaneously 
ON Points
100% (16 points/common) simultaneously ON (24 VDC)
Insulation Resistance20 MΩ between external terminals and GR terminal (at 100 VDC)
Dielectric Strength1,000 VAC between external terminals and GR terminal for 1 minute at a leakage current of 
10 mA max.
Internal Current 
Consumption
80 mA max.
Weight110 g max.
AccessoriesNone
Circuit Configuration
 
The signal names of the terminals are the device 
variable names. 
The device variable names are the names that use 
"Jxx" as the device name.
External connection and 
terminal-device variable 
diagram
 
The input power supply polarity can be connected in either direction. 
The signal names of the terminals are the device variable names. 
The device variable names are the names that use "Jxx" as the device name.
  • With quick-response inputs, pulse inputs shorter than the CPU Unit's cycle time can be read by the CPU Unit.
  • The pulse width (ON time) that can be read by the Quick-response Input Unit is 0.05 ms.
  • Inputs read by the internal circuits are cleared when inputs are refreshed.
* Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams. 
  They are not printed on the Units.

8-point/16-point Units (18-point Terminal Blocks)
CJ1W-IDP01

CJ1W-IDP01 Dimensions 2 CJ1W-IDP01_Dim

Dimensions CJ1W-INT01

CJ1W-INT01

CJ1W-INT01 Dimensions 2 CJ1W-INT01_Dim

Spesifications CJ1W-INT01

CJ1W-INT01 Interrupt Input Unit (16 Points)

Name16-point Interrupt Input Unit with Terminal Block
ModelCJ1W-INT01
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance3.3 kΩ
Input Current7 mA typical (at 24 VDC)
ON Voltage/ON Current14.4 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time0.05 ms max.
OFF Response Time0.5 ms max.
Number of Circuits16 (16 points/common, 1 circuit)
Number of Simultaneously 
ON Points
100% (16 points/common) simultaneously ON (24 VDC)
Insulation Resistance20 MΩ between external terminals and GR terminal (at 100 VDC)
DielectrQic Strength1,000 VAC between external terminals and GR terminal for 1 minute at a leakage current of 10 mA max.
Internal Current 
Consumption
80 mA max.
Weight110 g max.
AccessoriesNone
Circuit Configuration
Up to two Interrupt Input Units can be mounted to the 
CPU Rack. They must be connected as one of the five 
Units immediately next to the CPU Unit. If an Interrupt 
Input Unit is connected in any other position, an Incorrect 
Unit/Expansion Rack Connection error will occur. 
Set the pulse width of signals input to the Interrupt Input 
Unit so they satisfy the following conditions. 
The signal names of the terminals are the device variable 
names. 
The device variable names are the names that use "Jxx" 
as the device name.
External connection and 
terminal-device variable 
diagram
 
The polarity can be connected in either direction. 
The signal names of the terminals are the device variable names. The device variable names are the names 
that use "Jxx" as the device name.
Note: With NJ-series Controllers, Interrupt Input Units can be used as normal Basic Input Units. 
          They cannot be used to start I/O interrupt tasks. 
* Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams. 
   They are not printed on the Units.

CJ-series Interrupt Input Units CJ1W-INT01

High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs. This unit is available for CJ/NJ controller.

Features  CJ1W-INT01

High-speed ON response of 0.05 ms
Use up to 32 interrupt inputs with up to two Units per CPU Unit.
Applicable with both NPN and PNP output devices. Polarity selection is not required. *
* The same polarity is used for the same common.

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

Interrupt Input Units

Unit type: CJ1 Basic I/O Units
No. of words allocated: 1 word
Standards: UC1, N, L, CE
Product
name
SpecificationsCurrent
consumption (A)
Model
I/O pointsInput
voltage
current
CommonsInput pulse
width
conditions
Max. Units
mountable
per Unit
External
connection
5 V24 V
Interrupt
Input Unit
16 inputs24 VDC,
7 mA
16 points,
1 common
ON time:
0.05 ms max.
OFF time:
0.5 ms max.
2Removable
terminal block
0.08---CJ1W-INT01
Note: 1. Can be used only on CPU Racks, and not on Expansion Racks. 
           2. The locations where the Units can be mounted depend on the CPU Rack and the CPU Unit model. 
                CJ2H-CPU6[]-EIP: From the slot next to the CPU Unit until the fourth slot. 
                CJ1G, CJ1H: From the slot next to the CPU Unit until the fifth slot. 
                CJ1M: From the slot next to the CPU Unit until the third slot. 
           3. With the SYSMAC NJ-series Controllers,Interrupt Input Units can be used as normal Basic Input Units. They 
                cannot be used to start I/O interrupt tasks.

Accessories

There is no accessory for the CJ series Interrupt Input Units.

Dimensions CJ1W-MD

32-point Units (Mixed I/O Units)

With Fujitsu-compatible connector (24-pin × 2)
CJ1W-MD231

CJ1W-MD Dimensions 2

With MIL connector (20-pin × 2)
CJ1W-MD232
CJ1W-MD233

CJ1W-MD Dimensions 3

64-point Units (Mixed I/O Units)

With Fujitsu-compatible connector (40-pin × 2)
CJ1W-MD261

CJ1W-MD Dimensions 5

With MIL connector (40-pin × 2)
CJ1W-MD263
CJ1W-MD563

CJ1W-MD Dimensions 6

SERVO AMPLIFIER MITSUBISHI