CJ Series ID Sensor Unit CJ1W-V680C11 / V680C12

TypeAppearanceConnected ID 
System
External 
power 
supply
No. of unit 
numbers 
used
Current consumption 
(A)
Model
5 V24 VExternal
CJ 
Special 
I/O Unit
V680 
Series
1 Head-1 unit number0.260.13 *-CJ1W-V680C11
2 Heads2 unit number0.320.26-CJ1W-V680C12
* When connected to the V680-H01-V2: 0.28 A

General Specification

ModelCJ1W-V680C11CJ1W-V680C12
Current 
consumption
Internal: 5 V0.26 A0.32 A
Internal: 24 V/26 V0.13 A *0.26 A
External: 24 V--
Ambient operating temperature0 to 55°C
Ambient storage temperature-20°C to 75°C
Ambient operating humidity10% to 90% (with no condensation)
Insulation resistance20 mΩ min. at 500 VDC
Dielectric strength1,000 VAC for 1 minute
Degree of protectionMounted in panel (IP30)
Vibration resistance10 to 57 Hz variable vibration, 0.075-mm double amplitude and 57 to 150 Hz 
variable vibration at 9.8 m/s2 acceleration, with 10 sweeps in X, Y, and Z 
directions for 8 minutes each
Shock resistance147 m/s2 in X, Y, and Z directions 3 times each
Appearance31 × 65 × 90 mm (excluding protrusions)
Weight120 g max.130 g max.
* When connected to the V680-H01-V2: 0.28 A.

Performance Specifications

For CJ1 Series

ModelCJ1W-V680C11CJ1W-V680C12
Unit classificationSpecial I/O Unit
Influence on CPU 
Unit's cycle time
0.15 ms0.3 ms
Mounting locationCJ1-series CPU Rack or CJ1-series Expansion Rack 
(Cannot be mounted to C200H Expansion I/O Racks or SYSMAC BUS Slave Racks.)
Connectable 
Antennas
V680-series Amplifiers and Antennas *1
Applicable RF TagsV680-series RF Tags
No. of allocated 
units
12
No. of allocated 
words
10 words20 words
Control protocolSpecial protocol
Data exchange 
methods with CPU 
Unit
Special I/O Unit 
Area in CIO 
Area: CIO 2000 
to CIO 2959
Constant data 
exchange of 10 
words/Unit
CPU Unit to 
ID Sensor 
Unit
Unit controls, communications 
processing specification, data storage 
area specification
ID Sensor 
Unit to CPU 
Unit
Unit information, results information, 
processing results monitor
Special I/O Unit 
words in DM 
Area: D20000 
to D29599
100 words/Unit 
transferred when 
power is turned 
ON or when 
restarting the Unit
CPU Unit to 
ID Sensor 
Unit
System Settings, Auto Wait Time 
Setting, Write Protection Disable 
Setting, Antenna Connection Setting, 
Results Monitor Output, Test Setting, 
Run/Test Switching Method Setting
Data transfer 
quantity
2,048 bytes max. (160 bytes/scan) *22,048 bytes max./channel (160 bytes/scan) *2
Operating modesRun Mode
Test ModeCommunications tests 
Distance level measurements 
Read speed level measurements 
Write speed level measurements 
Noise level measurements 
Communications success rate measurements
Diagnostic 
functions
(1) CPU watchdog timer 
(2) Communications error detection with RF Tag 
(3) Antenna power supply error
*1. V680-H01 and V680-H01-V2 can be connected to 1CH-type ID Sensor Units only. They are not supported by 2CH- 
       type ID Sensor Units. 
*2. If using Intelligent I/O Instructions is specified as the data transfer method, up to 2,048 bytes can be transferred in 
       one scan.

For NJ Series

ModelCJ1W-V680C11CJ1W-V680C12
Unit classificationSpecial I/O Unit
Mounting locationNJ-series CPU Rack or NJ-series Expansion Rack
Connectable AntennasV680-series Amplifiers and Antennas *
Applicable RF TagsV680-series RF Tags
Operating modesRun Mode
Test ModeCommunications tests
Distance level measurements
Read speed level measurements
Write speed level measurements
Noise level measurements
Communications success rate measurements
Data exchange methods with CPU UnitData exchange by using I/O ports
Diagnostic functions(1) CPU watchdog timer
(2) Communications error detection with RF Tag
(3) Antenna power supply error
* V680-H01 and V680-H01-V2 can be connected to 1CH-type ID Sensor Units only. They are not supported by 2CH-type 
    ID Sensor Units.

Communications Function Specifications

ModelCJ1W-V680C11CJ1W-V680C12
Communications control(1) RF Tag Communications Speed (Normal Mode or High-speed Mode)
(2) Write Verification Processing
(3) Auto Wait Time Setting
(4) UID Addition Setting
(5) Write Protection Setting
(6) Antenna Connection Setting (One-channel ID Sensor Unit (CJ1W-V680C11))
(7) Results Monitor Setting
CommandsRead
Write
Bit Set/Bit Clear
Mask Bit Write
Calculation Write
Data Fill
Data Check
Number of Writes Control
Read with Error Correction
Write with Error Correction
UID Read
Noise Measurement
Read
Write
Bit Set/Bit Clear
Mask Bit Write
Calculation Write
Data Fill
Data Check
Number of Writes Control
Copy
Read with Error Correction
Write with Error Correction
UID Read
Noise Measurement
Communications specificationSingle trigger
Single auto
Repeat auto
FIFO trigger *
FIFO repeat *
Multi-access trigger *
Multi-access repeat *
* FIFO trigger, FIFO repeat, Multi-access trigger, and Multi-access repeat specification cannot be used for communicating 
   with V680-D1KP[][] RF Tags.

Connectable Units

When using V680-HS51/-HS52/-HS63/-HS65 Antenna

ModelNJ SystemCJ SystemCS System
CPU unitExpansion unitCPU unitExpansion unitCPU unitExpansion unit
CJ1W-V680C114 units6 units4 units4 unitsN/AN/A
CJ1W-V680C122 units3 units2 units2 unitsN/AN/A

When using V680-H01-V2 Antenna

ModelNJ SystemCJ SystemCS System
CPU unitExpansion unitCPU unitExpansion unitCPU unitExpansion unit
CJ1W-V680C112 units2 units2 units1 unitN/AN/A