 Item                                      Model
Appearance
3G3JX Variable Drives
3G3MX2 Variable Drives3G3RX Variable Drives

Power supply and capacity
Three-phase 200 V
0.2 to 7.5 kW
0.1 to 15 kW
0.4 to 55 kW
Single-phase/three-phase 200 V
0.2 to 2.2 kW
0.1 to 2.2 kW
None
Three-phase 400 V
0.4 to 7.5 kW
0.4 to 15 kW
0.4 to 132 kW
Control method
V/f control
Sensorless vector control
Vector control with a PG
Input/output
No. of multi-function I/O points
• 5 inputs
• 1 transistor output
• 1 relay output
• 7 inputs
• 2 transistor outputs
• 1 relay output
• 9 inputs (1 RUN (FWD)
input + 8 multi-function inputs)
• 5 transistor outputs
• 1 relay output
Analog I/O
• 1 input (0 to 10 V, 4 to 20 mA)
• 1 output (0 to 10 V)
• 2 inputs (0 to 10 V, 4 to 20 mA)
• 1 output (0 to 10 V)
• 2 inputs
(1) 0 to 10 V, 4 to 20 mA
(2) 0 to ±10 V

• 2 outputs
(1) 0 to 10 V
(2) 4 to 20 mA

• 1 PWM voltage output
Safety
Dual STO output 
 
EDM output 
 
Braking
Braking resistor connection
• (22 kW max.)
Regenerative Braking Unit connection
Regenerative Braking Unit + braking resistor connection
Frequency
Frequency setting range
0.5 to 400 Hz
0.1 to 400 Hz
0.1 to 400 Hz
Frequency output method
Line-to-line sine wave PWM

Installation and wiring
Side-by-side mounting
Removable terminal block
  
Power supply and motor wiring
Top/bottom wiring
Bottom wiring
Noise counter-measures
Radio noise filter
Standard feature (built-in)
Optional (external)
Standard feature (built-in)
I/O noise filter
Optional (external)
EMC filter
Optional (external)
Standard feature (built-in)
Operation
Digital Operator
Fixed Digital Operator (with adjustment dial)
Fixed Digital Operator
(without adjustment dial)
Removable Digital Operator
(without adjustment dial)
Autotuning
Main functions
Multistep speed control
16 steps + jog
Carrier frequency setting
2 to 12 kHz (default setting: 3 kHz)
2 to 15 kHz (default setting: 10 kHz)
2 to 15 kHz (default setting: 5 kHz)
Torque assist function
Manual + auto torque assist
Auto (simple)/manual torque assist
Auto/manual torque assist
PID function
Absolute value positioning
Emergency shutoff
0-Hz domain sensorless vector control
 
Tripless function
Momentary power interruption restart
Automatic energy saving
 
Communications
MODBUS-RTU
RoHS
Safety standards
CE
UL/cUL
PLd
(ISO 13849-1: 2006)