CJ1W-PA / PD CJ-series Power Supply Unit: CJ1W-PA205C,CJ1W-PA205R,CJ1W-PA202,CJ1W-PD025,CJ1W-PD022


- AC Power Supply Unit, Power supply Voltage 100 to 240 VAC, Output capacity 5-VDC output capacity 5 A 24-VDC output capacity 0,8 A Total power consumption 25 W,  Options 24-VDC service power supply No RUN output No Maintenance forecast monitor Yes  : CJ1W-PA205C
- AC Power Supply Unit, Power Supply Voltage 100 to 240 VAC, 5-VDC output Capacity 5 A 24-VDC output capacity 0,8 A Total Consumption 25 W, Options 24-VDC service power supply No, RUN output No, Maintenance forecast monitor Yes  : CJ1W-PA205R
- AC Power Supply Unit, Power Supply Voltage 100 to 240 VAC, Output capacity 5-VDC output capacity 2,8 A 24-VDC output capacity 0,4 A Total Power consumption 14 W,  Options 24-VDC service power supply No RUN output No Maintenance forecast monitor No  : CJ1W-PA202
- DC Power Supply Unit, Power supply Voltage 24 VDC, Output capacity 5-VDC Output capacity 5 A 24-VDC Output capacity 0,8 A Total power Consumption 25 W, Options 24 VDC Service power supply No RUN output No Maintenance forecast monitor No   : CJ1W-PD025
- DC Power Supply Unit, Power supply Voltage 24 VDC,  Output Capacity 5-VDC Output capacity 2 A 24-VDC output capacity 0,4 A Total Power Consumption 19,6 W, Options 24-VDCservice power supply No, RUN output No Maintenance forecast monitor No  : CJ1W-PD022

CJ2H CPU Units: CJ2H-CPU68,CJ2H-CPU67,CJ2H-CPU66,CJ2H-CPU65,CJ2H-CPU64

- CJ2H CPU Units, I/O Capacity/ Mountable Units (Expansion Racks) 2,560 points/ 40 units (3 Expansion Racks max), Program Capacity 400K steps, Data Memory Capacity 832K words DM 32K words EM 32 Words x 25 banks, LD Instruction execution time 0,016 us, Current Consumption (A) 5 V 0,42 * : CJ2H-CPU68
- CJ2H CPU Units, I/O Capacity/ Mountable Units (Expansion Racks) 2,560 points/ 40 Units (3 Expansion Racks max), Program Capacity 250K words dm 32K words EM 32K words x 15 banks, Data Memory Capacity 512K words DM 32K words EM words x 15 bank, LD instruction Execution time 0,026 us, Current Consumption (A) 5 V 0,42  : CJ2H-CPU67
- CJ2H CPU Units, I/O Capacity/ Mountable Units (Expansion Racks) 2,560 points/40 Units (3 Expansion Racks max), Program Capacity 150K steps, Data Memory capacity 352K words DM 32K words EM 32K words x 10 banks, LD Instruction execution time 0,016 us, Current Consumption (A) 5 V 0,42 *  : CJ2H-CPU66
- CJ2H CPU Units, I/O Capacity/ Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max), Program Capacity 100K,steps, Data Memory Capacity 160K words DM 32K words EM 32K words x 4 banks, LD Instruction execution time 0,016 us, Current Consumption (A) 5 V 0,42 *  : CJ2H-CPU65
- CJ2H CPU Units, I/O Capacity/ Mountable Units (Expansion Racks) 2,560 points/40 Units (3 Expansion Racks max), Program Capacity 50K , Data Memory Capacity 160K words DM 32K words EM 32K words x 4 banks, LD Instruction execution time 0,016 us, Current Consumption (A) 5 V 0,42 *  : CJ2H-CPU64

CJ2H (Built-in EtherNet/IP) CPU Units: CJ2H-CPU68-EIP, CJ2H-CPU67-EIP,CJ2H -CPU66-EIP,CJ2H-CPU65-EIP,CJ2H-CPU64-EIP


- CJ2H (Built-in EtherNet/IP) CPU Units, I/O Capacity/Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max), Program Capacity 400K steps,  Data Memory capacity 823K words DM 32K words EM 32K words x 52 banks, LD Instruction execution time 0,016 us, Current Consumption (A) 5 V 0,82 * : CJ2H-CPU68-EIP
- CJ2H (Built-in EtherNet/IP) CPU Units, I/O Capacity/Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max),Program Capacity 250K steps, Data Memory Capacity 512K words DM 32K words EM 32K words x 15 banks, LD Instruction execution time 0,016 us, Current Consumption (A) 5 V 0,82 *  : CJ2H-CPU67-EIP
- CJ2H (Built-in EtherNet/IP) CPU Units, I/O Capacity Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max), Program Capacity150K steps,Data Memory Capacity 352K words DM 32K words EM 32K words x 10 banks, LD instruction execution time 0,06 us, Current Consumptions (A) 5 V 0,82 * : CJ2H -CPU66-EIP
-  CJ2H (Built-in EtherNet/IP) CPU Units, I/O Capacity Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max), Program Capacity 100K steps, Data Memory Capacity  160K words DM 32K words EM 32K words x 4 banks, LD instruction execution time 0,06 us, Current Consumption (A) 5 V 0,82 *  : CJ2H-CPU65-EIP
- CJ2H (Built-in EtherNet/IP) CPU UNITS, I/O Units Capacity Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max), Program Capacity 50K steps, Data Memory Capacity 160K words DM 32K words EM 32K words x 4 banks,  LD Instruction execution time 0,06 us, Current Consumption (A) 5 V 0.82  : CJ2H-CPU64-EIP

Pulse I/O Modules (Only CJ2M CPU Unit with Unit Version 2.0 or Later): CJ2M-MD211,CJ2M-MD212


- Pulse I/O Modules, Specifications Sinking outputs, MIL connector 10 Inputs (including four interrupt/quick response inputs and two high-speed counter inputs) 6 outputs (including two pulse outputs and two PWM outputs), Current Consumption (A) 5 V 0.08 : CJ2M-MD211
- Pulse I/O Modules, Specifications Sourcing outputs MIL connector CE 10 inputs (including four interrupt/quick response inputs and two high-speed counter inputs) 6 outputs (including two pulse outputs and two PWM outputs), Current Consumption (A) 5 V 0.08  : CJ2M-MD212

Serial Communications Option Boards (Only CJ2M-CPU3[]): CP1W-CIF01,CP1W-CIF11,CP1W-CIF12


- RS-232C Option Board, Specification One RS-232C port Connector D-sub 9 pin female Maximum transmission distance 15m, Serial communications mode Host link 1 N NT Link Noprotocol Serial PLC Link Slave Serial PLC Link Master Serial Gateway Converted to  CompoWay/F and Tool Bus *, Current Consumption (A) 5 V 0,005  : CP1W-CIF01
- RS-232C Option Board, Specification One RS-422C port Terminal block using ferrulse Maximum transmission distance 50 m, Serial Communications mode Host Link 1 N NT Link Noprotocol Serial PLC Link Slave Serial PLC Link Master Serial Gateway Converted to compoWay/F and Tool Bus 8*, Current Consumption (A) 5 V 003 : CP1W-CIF11
- RS-232C Option Board, Specifications One RS-422A/485 port (Isolated) Terminal block using ferrules Maximum transmission distance 500m, Serial communications mode Host Link Noprotocol Serial PLC Link Slave Serial PLC Link Master Serial Gateway converted to CompoWy/F and Tools Bus * Current Consumption (A) 5 V 0,075  : CP1W-CIF12

CJ2M CPU Units: CJ2M-CPU15,CJ2M-CPU14,CJ2M-CPU13,CJ2M-CPU12,CJ2M-CPU11

- CJ2M CPU Units, I/O Capacity /Mountable Units (Expansion Racks) 2,560 points/40 Units (3 Expansions Racks max), Program capacity 60K steps, Data Memory capacity 160K words (DM 32K words EM 32K words x 4 banks), LD instructions execution time 0,04 us, EtherNet/IP unction - , Option boards slot - , Current Consumption (A) 5 V 0,5 *  : CJ2M-CPU15
- CJ2M CPU Units, I/O Capacity/Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max), Program capacity 3oK steps, Data Memory capacity 160K words (DM 32K words EM 32K words x 4  banks) , LD Instruction execution time 0,04 us, EtherNet/IP function - , Option boards - , Current Consumption (A) 5 V 0,5 *  : CJ2M-CPU14
- CJ2M CPU Units , I/O Capacity Mountable Units (Expansion Racks) 2,560 points/40 Units (3 Expansion Racks max), Program capacity 20K steps, Data Memory capacity 64K words (DM 32K words EM 32K words x 1 banks), LD instruction execution time 0,04 us, EtherNet/IP function - , Option board slot - , Current Consumption (A) 5 V 0,5 *  : CJ2M-CPU13
- CJ2M CPU Units, I/O Capacity Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max), Program capacity 10K steps, Data Memory Capacity 64K words (DM 32K words EM 32K words x 1 banks ) , LD instruction execution time 0,04 us, EtherNet/IP function- , Option boards slot -, Current Consumption (A) 5 V 0,5 *  : CJ2M-CPU12
- CJ2M CPU Units, I/O Capacity Mountable Units (Expansion Racks ) 2,560 points/40 units (3 Expansion Racks max), Program capacity 5K steps, Data Memory capacity 64K words (DM32K words EM 32K words x 1 banks), LD instruction execution time 0,04 us, EtherNet/IP function-, Option board slot-, Current Consumption (A) 5 V 0,5 * : CJ2M-CPU11

CJ2M CPU Units (Built-in EtherNet/IP) : CJ2M-CPU35, CJ2M-CPU34,CJ2M-CPU33,CJ2M-CPU32,CJ2M-CPU31


- CJ2M (Built-in EtherNet/IP) CPU Units, I/O capacity Mountable Units (Expansion Racks) 2,560 points/40 Units (3 Expansion Racks max), Program capacity 60K steps, Data Memory capacity 160K words (DM 32K words) EM 32K words x 4 banks), LD instruction Execution time 0,04 us, EtherNet/IP function YES, Option board slot YES, Current Consumption (A) 5 V 0,7 *    : CJ2M-CPU35
- CJ2M (Built-in EtherNet/IP) CPU Units, I/O Capacity Mountable Units (Expansion Racks) 2,560 points/40 Units (3 Expansion Racks max), Program capacity 30K steps, Data Memory capacity 160K words (DM 32K words EM 32K words x 4 banks) LD instruction Execution time 0,04 us , EtherNet/IP function YES, Option board slot YES, Current Consumption (A) 5 V  0,7 *   :  CJ2M-CPU34
- CJ2M (Built-in EtherNet/IP), I/O Capacity Mountable Units (Expansion Racks0 2,560 Points/40 Units (3 Expansion Racks max), Program Capacity 20K steps, Data Memory capacity 64K words (DM 32K words EM 32K words x 1 bank), LD instruction Execution time 0,04 us, EtherNet/IP YES, Option board YES, Current Consumption (A) 5 V 0,07 *  :  CJ2M-CPU33
- CJ2M (Built-in EtherNet?IP) CPU Units, I/O capacity Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max), Program capacity  10K steps, Data Memory capacity64K words (DM 32K words em 32k words x 1 bank), LD instruction execution time 0,04 us, EtherNet/IP function YES, Option board slot YES, Current Consumption (A) 5 V 0,7  * : CJ2M-CPU32
- CJ2M (Built-in) CPU Units, I/O Capacity Mountable Units (Expansion Racks) 2,560 points/40 Units (ExpansionRacks max), LD instruction execution time 0,04 us, EtherNet/IP function YES, Option board slot YES, Current Consumption (A) 5 V 0,7 *   : CJ2M-CPU31

CJ1W-IC / II CJ-series I/O Control Unit / I/O Interface Unit


- CJ-series I/O Control Unit, Specifications Mount one I/O Control on the CPU Rack when connecting on or more Expansion Racks Connecting Cable CS1W-CN[][]3 Expansion Connecting Cable Connected Unit CJ1W-II101 I/O Interface Unit Mount to the right of the CPU Unit, Current Consumption (A) 5 V 0,02  : CJ1W-IC101

Kamis, 27 Juli 2017

CJ1W-NC[]71 CJ-series Position Control Unit with MECHATROLINK-II interface: CJ1W-NC271,CJ1W-NC471,CJ1W-NCF71, CJ1W-NCF71-MA


- CJ1 CPU Bus Units, Position Control Unit with MECHATROLINK-II interface, Control output interface Control commands executed by MECHATROLINK-II synchronous communications Direct operation by ladder programming Control mode Position control speed control or torque control, No of axes 2, N of unit numbers allocated 1, Current Consumption (A) 5 V  0.36  : CJ1W-NC271
- CJ1 CPU Bus Units, Position Control Unit with MECHATROLINK-II interface, Control output interface Control commands executed by MECHATROLINK-II synchronous communications Direct operation by ladder programming Control mode Position control speed Control or torque control, No of axes 4 axes, No of unit numbers allocated 1, Current Consumption (A) 5 V 0,36  : CJ1W-NC471
- CJ1 CPU Bus Units, Position Control Unit with MECHATROLNK-II synchronous communications Direct operation by ladder programming Control mode  position control speed control or torque control, No of axes 16 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0,36  : CJ1W-NCF71
- CJ1 CPU Bus Units, Position Control Unit MECHATROLINK-II interface, Control output interface Control commands MECHATROLINK-II synchronous communications Direct Operation by ladder Programming Control mode position control or torque control, No of axes 16, No of units  numbers allocated 1, Current consumption (A) 5 V  0,36  : CJ1W-NCF71-MA

CJ1W-SPU01-V2 CJ-series High-speed Data Storage Unit (SPU Unit)


- CJ1 CPU Bus Units, SPU Unit (High speed Data storage Unit) PC Card slot CF Card Type I/II x 1 slot Use an OMRON HMCEF   Memory card, Ether (LAN) port 1 port (10/100Base-TX), No of unit Numbers allocated 1, Current consumption (A) 5 V 0.56  : CJ1W-SPU01-V2

CJ1W-EIP21 CJ-series EtherNet/IP Unit


- CJ1 CPU Bus Units, EtherNet/IP Unit, Communications functions shielded twisted-pair (STP) cable categories, Communications Functions Tag Data link Functions Message Communications Functions, Units per CPU Unit 8 max *1 , No of unit numbers allocated 1, Current consumption (A) 5 V 0.41 : CJ1W-EIP21 *2

CJ1W-NC[]81 / []82 CJ-series Position Control Units with EtherCAT interface: CJ1W-NC281,CJ1W-NC481,CJ1W-NC881,CJ1W-NCF81,CJ1W-NC482,CJ1W-NC882,CJ1W-NCF82


- CJ1 CPU Bus Units, Position Control Units with Ether Cat interface, Control output interface control commands executed by EtherCAT Communications positioning function Memory operation Direct operation by ladder programming, No of axes 2 axes, No unit numbers allocated 1, Current Consumption (A) 5 V 0.46   : CJ1W-NC281
- CJ1 CPU Bus Unit, Position Control Units with Ether CAT interface, Control output interface Control commands executed by EtherCAT communications positioning Function Memory operation Direct Operation by ladder Programming, No of axes 4 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0.46  : CJ1W-NC481
- CJ1 CPU Bus Unit, Position Control Units with EtherCAT interface, Control output interface Control commands  executed by EtherCAT communications positioning Functions Memory operation Direct operation by ladder programming, No of axes 8 axes, No f unit numbers allocated 1, Current Consumption (A) 5 V 0.46  : CJ1W-NC881
- CJ1 CPU Bus Units, Position Control Units with EtherCAT interface, Control output interface Control commands executed EtherCAT communications positioning function Memory operation Direct operation by ladder programming, No of axes 16 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0,46   : CJ1W-NCF81
- CJ1 CPU Bus Unit, Position Control Units with EtherCAT interface, Control output interface Control commands executed by EtherCAT communications Positioning function Memory operation Direct operation by ladder programming I/O communications 64 nodes, No of axes 4 axes, No of unit numbers allocated 1, Current Consumption (A) 5 V  0,46  : CJ1W-NC482
- CJ1 CPU Bus Units , Position Control Units with EtherCAT interface, Control output interface Control commands executed by EtherCAT communications Positioning function Memory operation Direct operation by ladder programming I/O communications 64 nodes, No of axes 8 axes, No of unit numbers allocated 1, Current Consumption (A) 5 V 0.46  : CJ1W-NC882
- CJ1 CPU Bus Units, Position Control units with EtherCAT interface, Control output interface Control commands executed by EtherCAT positioning function Memory operation Direct operation by ladder programmingI/O communication 64 nodes, No of axes 16 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0.46  : CJ1W-NCF82

CJ1W-ECT21 CJ-series EtherCAT® Slave Unit


- CJ1 CPU Bus Unit, Ether Cat Slave Unit, Communications cable STP (shielded twisted-pair) cable of category 5 or higher with double shielding,Comunications Functions Refreshing methods Free-Run Mode PDO data sizes TxPDO 400byte max/ RxPDO 400 byte max, No of Unit numbers allocated 1, Current consumption (A) 5 V 0.34  : CJ1W-ECT21*

CJ1W-PH41U / AD04U CJ-series Process Analog I/O Unit: CJ1W-AD04U,CJ1W-PH41U*2



- Proces Input Units (Isolated type Units With Universal Inputs), Signal range Fully universal inputs pt100 JPt100 Pt1000 K J L R S  B  4  to 20 mA  0 to 20 mA 1 to 5 V 0 TO 5 V 0 to 10 V, Conversion speed (resolution)  Conversion speed 250 ms/ 4 inputs, Accuracy (at ambient Temperature of 25 C) Accuracy Platinum resistance thermometer input (+ 0.3% of PV OR +0.8 C whichever is large) + 1 digit max Thermocouple input (+0.3% of PV or + 1,5 C whichever is large) + 1 digit max *1 Voltage or current input +0.3% of F S +1 digit max, Current Consumption (A) 5 V 0.32   : CJ1W-AD04U
- Proces Input Units (Isolated type Units with Universal Inputs), Signal range Universal Input Pt100 (3-wire) JPt100 (3-wire) Pt1000 (3-wire) Pt100 (4-wire) K J T E L U N R S B WRe5-26 PL II 4 to 20 mA 0to 20 mA 1 to 5 V 0 to 1,25 V 0 to 5 V 0to 10 V +100 mV selectable -1,25 to 1,25 V -5 TO 5 V -10 t0 10 V +10 V selectable range potentiometer, Conversion speed (resolution) Resolution (conversion speed) 1/256,000 (conversion cycle 60 ms/ 4 inputs) 1/64,000 (Conversion cycle 5 ms/ 4 inputs), Accuracy (at ambient temperature) of 25 C) standard Accuracy +0.05% 0f F S, Current Consumption (A) 5 V 0.3   : CJ1W-PH41U*2

CJ1W-SRM21 CJ-series CompoBus/S Master Uni


- CJ1 Special I/O Units, Compo Bus/S Master, Communications functions Remote I/O Communications, No of I/O points 256 max (128 inputs and 128 outputs), max Units mountable per CPU Unit 40, No of numbers unit allocated 1 or 2 (variable), Current Consumption (A) 5 V 0.15  : CJ1W-SMR21
- CJI Special I/O Units, Compo Bus/S Master Unit, Communications functions Remote communications, No of I/D points 128 max (64 inputs and 64 outputs), Max Units mountable per CPU Unit 40, No of unit numbers allocated  1 or 2 (variable), Current Consumption (A) 5 V 0.15 : CJ1W-SRM21

CJ1W-V680C11 / V680C12 CJ Series ID Sensor Uni: CJ1W-V680C11,CJ1W-V680C12


- CJ Special I/O Unit, Connected ID system 1 Head, External power supply - , No of Numbers used 1 Unit number, Current Consumption (A) 5 V 0.26  24 0.13* External -     : CJ1W-V680C11
- CJ Special O/I Unit, Connected ID system 2 Heads , External power supply - , No of Numbers used 2 Unit Number, Current Consumption 5 V 0.32 24 V 0.26 External -    : CJ1W-V680C12

CJ1W-CT021 CJ-series High-speed Counter Unit


- CJ1 Special I/O Units, High Speed Counter Unit, Countable Channels 2, Encoder A and B inputs pulse input Z signal Open collector input Voltage 5 VDC 12 V or 24 V (5 V and 12 V are each for one axis line driver, Max counting rate 50 KHz  500 KHz, No of Numbers allocated, Current Consumption (A) 5 V 0.28 : CJ1W-CT021

CJ1W-NC[][]3 CJ series Position Control Units: CJ1W-NC113,CJ1W-NC213,CJ1W-NC413,CJ1W-NC133,CJ1W-NC233,CJ1W-NC433,CJ1W-SP001



- CJ1 Special I/O Units,Position control unit,  Control Method/Control output interface Open-loop control by pulse train output/Open Collector output, Number of Control axes 1 axis, Current Consumption (A) 5 V 0.25 : CJ1W-NC113
- CJ1 Special O/I Units, Position Control unit, Control Method/Control output interface Open-loop Control by pulse trein output/Open Collector output, Number of Control axes 2 axes, No of numbers allocated - , Current Consumption (A) 5 V 0.25 : CJ1W-NC213
- CJI Special I/O Units, Position Control Unit, Control Method/Control Output interface Open-loop control by pulse train output/Open collector output, Number of Control axes 4 axes, No of Unit Numbers allocated 2, Current Consumption (A) 5 V 0.36  : CJ1W-NC413
- CJ1 Special I/O Units, Position Control Unit, Control Method/Control Output interface Open-loop control by pulse train output/line-driver output, Number of control axes 1axis, No of Numbers allocated 1, Current Consumption (A) 5 V 0.25 : CJ1W-NC133
- CJ1 Special I/O Units, Position Control Unit, Control Method/Control output interface Open-loop  control by pulse train output/line driver output, Number of axes 2 axes, No of Numbers allocated 1, Current Consumption (A) 5 V 0.25  : CJ1W-NC233
- CJ1 Special I/O Units, Position Control Unit, Control Method/Control output interface Open-loop control by pulse trein output/line-driver output, Number of axes 4 axes, No of Numbers allocated 2, Current Consumption (A) 5 V 0.36  : CJ1W-NC433
-CJ1 Special I/O Units, Space Unit, Control Method/Control output interface The ambient operation temperature range can be increased to 0 to 55 C if the CJ1W-SP001 CJ-Series Space Unit is used  : CJ1W-SP001

CJ1W-NC[][]4 CJ-series Position Control Units (High-Speed type) : CJ1W-NC214,CJ1W-NC414,CJ1W-NC234,CJ1W-NC434


- CJ1 Special I/O Units, Position Control Units (High speed type), Control Method/Control output interface pulse-train open collector output with pulse Counter Function, Number of control axes 2 axes, No of unit numbers allocated 2, Current consumption (A) 5 V system 0.27   : CJ1W-NC214
- CJ1 Special I/O Units, Position Control Units (High speed type), Control Method/Control output interface pulse-train open collector output with pulse Counter Function,  Number of control axes 4 axes, No of unit numbers allocated 2, Current Consumption (A) 5 V system 0.31  : CJ1W-NC414
- CJ1 Special I/O Units, Position Control Units (High speed type), Control Method/Control output interface pulse-train line-driver output with Pulse Counter Function, Number of Control axes  2 axes, No of unit numbers allocated 2, Current Consumption (A) 5 V system 0.27 : CJ1W-NC234
- CJI Special I/O Units, Position Control Units (High speed type), Control Method/Control output interface Pulse-train line-driver output with Pulse Counter Function, Number of control axes 4 axes, No of Unit numbers allocated 2, Current Consumption (A) 5 V 0.13  : CJ1W-NC434

CJ1W-TC CJ Series Temperature Control Unit: CJ1W:TC001 * ,CJ1W-TC002 * ,CJ1W-TC003,CJ1W-TC004, CJ1W-TC101*, CJ1W-TC102*, CJ1W-TC103*, CJ1W-TC104


- CJ1 Special I/O Units, Temperature Control Units, No of loops 4 loops, Temperature sensor inputs Thermocouple inputs R S K J T B L, Control outputs Open Collector NPN output (pulses), Unit Numbers allocated 2 , Current consumption (A) 5 V 0.25 : CJ1W:TC001 *
- CJI Special I/O Units, Temperature Control Units, No of loops 4 loops, Temperaturesensor inputs inputs Thermocouple inputs R S K J B L, Control outputs Open Collector PNP outputs (pulses), Unit Numbers allocated 2, Current Consumption (A) 5 V  0.25 : CJ1W-TC002 *
- CJI Special I/O Units, Temperature Control Units, No of loops 2 loops heater burnout detection function, Temperature sensor inputs Thermocouple  inputs R S K J T B L, Control outputs Open Collector NPN output (pulses), Unit Numbers allocated 2, Curren consumption  (A) 5 V 0.25  : CJ1W-TC003
-CJI Special I/O Units, Temperature Control Units, No of loops 2 loops heater burnout detection function, Temperature sensor inputs Thermocouple inputs R S K J T B L, Control outputs Open Collector PNP outputs (pulses), Unit Numbers allocated 2, Current consumption (A) 5 V 0.25 : CJ1W-TC004
- CJI Spesial I/O Units, Temperature Control Units, No of loops 4 loops, Temperature sensor inputs Platinum resistance thermometer input (jPt 100,pt1100), Control outputs Open Collector PNP outputs (pulses), Unit Numbers allocated 2, Current Consumption (A) 5 V 0.025  : CJ1W-TC101*
- CJI Special I/O Unit, Temperature Control Units, No of loops 4 loops, Temperature sensor inputs Platinum resistance thermometer input (jPt 100,pt1100), Control outputs  Open Collector NPN outputs (pulses), Unit Numbers allocated 2 , Current Consumption (A) 5 V 0.25  : CJ1W-TC102*
- CJI Special I/O Unit, Temperature Control Units, No of loops 2 loops heater burnout detection function, Temperature sensor inputs Platinum resistance thermometer input (jPt 100,pt1100), Control outputs Open Collector NPN output (pulses), Unit Numbers allocated 2, Current Consumption (A) 5 V 0.25 : CJ1W-TC103*
- CJI Special I/O Units, Temperature Control Units, No of loops 2 loops heater burnout detection function, Temperature sensor inputs Platinum resistance thermometer input (jPt100,pt11,00), Control outputs Open Collector PNP outputs (pulses), Unit Numbers allocated 2, Current Consumption (A) 5 V 0.25  : CJ1W-TC104

Rabu, 26 Juli 2017

CJ1W-PDC15 CJ-series Process Analog I/O Unit


- CJ1 Special I/O Units, Isolated type DC Input Units, Input points 2 points, Signal range selection DC Voltage 0 to 1,25 V -1.25 to 1.25 V 0 to 5 V 1 to 5 V -5 to 5 V 0 to 10 V -10 to 10 v +10V selectable range   DC current O to 20 mA 4 to mA, Conversion speed (resolution 1/64,000), Accuracy (at ambient temperature of 25 C ) Accuracy +0.05% of F.S. , External connection Removable terminal block, No of unit numbers allocated 1, Current consumption (A)  5V 0.18 24 V 0.09 : CJ1W-PDC15

CJ-Series Analog I/O Unit CJ1W-AD / DA / MAD: CJ1W-AD042,CJ1W-AD081-V1,CJ1W-AD041-V1


- Analog Input Unit (High speed type) , I/O 4 inputs, Signal range 1 to 5 V (1/10,000) 0 to 10 V (1/20,000) -5 to 5 V (1/20,000) -10 to 10 (1/40,000) and 4 to 20 mA (1/10,000) , Conversion period 20 us/1 point 25 us/2 point 30 us/3 points 35 us/4 points The Direct conversion is perovided *1, Accuracy at ambient temperature of 25 C Voltage +0.2% of F.S. Current +0.4% of F.S.  , Current consumption (A) 5 v 0.52    : CJ1W-AD042
- Analog Inputs Units, I/O points 8 inputs, Signal range 1 to 5 V 0 tO 5 V  0 to 1o V -10 to 10  V 4 to 20 mA, Resolution 1/4,000 (Settable to 1/8,000)*2 , Conversion period 1 ms/point (250 us/point can also be set.)*2 , Accuracy at ambient temperature of 25 C  Voltage +0.2% of F.S. Current +0.4 of F.S.*3 Current consumption (A) 5 V 0.42 : CJ1W-AD081-V1
- Analog Inputs Units, I/O points 4 inputs, Signal range 1 to 5 V 0 to 5 V 0 to 10 V -10 to 10 V 4 to 20 mA , Resolution 1/4,000 (Settable to 1/8,000)*2, Conversion period 1 ms/point (250 us/point can also be set )*2 , Accuracy at ambient temperature of 25 C  Voltage +0.2% of  F.S. Current +0.4% of F.S.*3,Current consumption (A) 5 V 0.42   : CJ1W-AD041-V1

CJ1W-PTS CJ-series Process Analog I/O Unit

- Process Input Units (Isolated type Thermocouple Input Units), Input points 2 inputs, Signal range selection Set separately for each input, Signal range Thermocouple  B E J K L N R S T U  Wre5-26 PLII DC voltage + 100 mV, Conversion speed (resolution) Conversion speed 10 10 ms/ 2 inputs Resolution  1/64,000 , Accuracy (at ambient temperature 25 C) standar accuracy  External connection Removable terminal block, No of unit numbers allocated, 1 , Current consumption (A) 5 V 0.18  24 V 0.06 *2 : CJ1W-PTS15
- Proces Input Unit (Isolated type Thermocouple Input Units), Input points 4 inputs, Signal range selection Common inputs, Signal range selection Thermocouple R S K J T L B , Conversion speed (resolution) Conversion speed 250 ms/ 4 inputs, Accuracy ( at ambient temperature of 25 C ) Accuuracy (+0.05% of PV), External connection Removable terminal block, No of unit numbers allocated 1, Current consumption (A) 5 V 0.25 :  CJ1W-PTS51

CJ1W-CRM21 CJ-series CompoNet Master Units

- CJ1 Special I/O Unit, Type communications Remote I/O communications Message communication, Maximum number of I/O points per Master Unit, Number of Unit numbers allocated, Power consumption (A) 5-V system 0.4  : CJ1W-CRM21

CJ-series B7A Interface Unit CJ1W-B7A: CJ1W-B7A14,CJ1W-B7A04,CJ1W-B7A22


- CJ1 Basic I/O Units, B7A Interface Units, I/O 64 inputs , External connection Removable terminal block, No of words allocated 4 words, Current consumption (A) 5 V 0.07   : CJ1W-B7A14
- CJ1 Basic I/O Units, B7A interface Units, I/O 64 output, External connection Removable terminal block, No of words allocated 4 words, Current consumption (A) 5 V 0.07  : CJ1W-B7A04
- CJI Basic I/O Units, B7A Interface Units, I/O 32 inputs/outputs External connection Removable terminal black, Current consumption (A) 5 V 0.07 : CJ1W-B7A22

CJ1W-IDP01 CJ-series Quick-response Input Units


- Quick response Input Unit, I/O points 16 inputs, Input Voltage current 24 VDC 7 mA, Commons 16 points 1 common, Input pulse width conditions ON time 0.05 ms max OFF time 0.5 ms max, External connection Removable terminal block Currenr consumption (A) 5 V 0.08 : CJ1W-IDP01

CJ-series Interrupt Input Units CJ1W-INT01


- Interrupt Input Unit, I/O points 16 points, Input Voltage current 24 VDC 7 mA, Commons 16 points 1 common, Input width conditions On time 0.05 ms max OFF time 0.5 ms max. MaxUnits mountable per Unit 2 , Exernal connection Removable terminal block, Current consumption (A) 5V 0.08  : CJ1W-INT01

CJ-series Mixed I/O Units CJ1W-MD :CJ1W-MD231,CJ1W-MD233, CJ1W-MD261,CJ1W-MD263,CJ1W-MD232,CJ1W-MD563



- DC Input Transistor Output Units, Output type sinking, I/O points 16 inputs 16 Output, Input Voltage input current 24 VDC 7 mA Commons 16 points 1 common, Maximum switching capacity 250 VAC/24 VDC 0.5 A Commons 16 points 1 common, External connection Fujitsu connector, No of words allocated 2 words, Current consumption (A) 5 V 0.13 : CJ1W-MD231
- DC Input Transistor Output Units, Output type sinking, I/O points 16 inputs 16 Output, Input Voltage input current 24 VDC 7 mA Commons 16 points 1 common, Maximum switching capacity 12 to 24 VDC 0.5 A Commons 16 points 1 common, External connector MIL connector, Current consumption (A) 5 V 0.13  : CJ1W-MD233
- DC Input Transistor Units, Output type sinking, I/O points 32 Inputs 32Output, Input Voltage input current 24 VDC 4,1 mA Commons 16 points 1 common, Maximum switching capacity 12 to 24 VDC 0.3 A, Commons 16 point 1 common, External connection Fujitsu connector, Current consumption (A) 5 V 0.14  : CJ1W-MD261
- DC Input Transistor Units, Output type sinking, I/O points 32 Inputs 32 Output, Input Voltage input current 24 VDC 4.1 mA Commons 16 points 1 common, Maximum switching capacity 12 to 24 VDC 0.3 A Commons 16 point 1 common, External connection MIL connector, No of words allocated 4 words, Current consumption (A) 5 V 0.14  : CJ1W-MD263
- DC Input Transistor Units, Output type Sourcing, I/O points 16 inputs 16 outputs, Input Voltage input current 24 VDC 7 mA Commons 16 points 1 common, Maximum switching capacity 24 VDC 0.5 A Shortcircuit protection Commons 16 points 1 common, External connection MIL connector, No  of words allocated 2 words, Current consumption  (A) 5 V 0.13   : CJ1W-MD232
- TTL I/O Units, Output type - , I/O points 32 inputs 32 output, Input Voltage input curent 5 VDC 35 mA Commons 16 points 1 common , Maximum switching capacity 5 VDC 35 mA Commons 16 points 1 common, External connection MIL connector, No of words allocated 4 words, Current consumption CJ1W-MD563

Selasa, 25 Juli 2017

CJ-series Output Units CJ1W-OC / OA / OD : CJ1W-OC201,CJ1W-OC211,CJ1W-OA201,CJ1W-OD201,CJ1W-OD203,CJ1W-OD211,CJ1W-OD213,CJ1W-OD231,CJ1W-OD233,CJ1W-OD234,CJ1W-OD261,CJ1W-OD263, CJ1W-OD202,CJ1W-OD204,CJ1W-OD212,CJ1W-OD232, CJ1W-OD262



- Relay contact output Units, output type - , I/O points 8 outputs, maximum switching capacity 250 VAC/ 24 VDC 2 A, commons indepent connectioon contacts, External connection Removable terrminal blok, No of words allocated 1 words, current consumption (A)  5 V  0.09  24 V 0.048 max : CJ1W-OC201
- Relay contact output Units, output type - , I/O points 16 outputs, Maximum switching capacity 250 VAC/ 24 VDC 2 A, commons 16 points 1 common, External connection Removable terminal block, No of words allocated 1 words, current consumption (A) 5 V  0.11  24 V  0.096 max : CJ1W-OC211
- Relay contact output Units, output type -, I/O points 8 outputs, Maximum switching capacity 250 VAC  0.6 A, commons 8 points 1 common, External connection Removable terminal block, No of words allocated 1 words, current consumption (A) 5  V 0.22   : CJ1W-OA201
- Relay contact outputs Units, output type  sinking ,  I/O points 8 outputs, Maximum switching capacity 12 to 24 VDC 2 A, commons 4 points 1 common, External connection Removable terminal block, No of words allocated 1 words, current consumption (A) 5 V 0.09  : CJ1W-OD201
- Relay contact output Units, output type sinking, I/O points 8 outputs, Maximum switching  capacity 12 t0o 24 VDC 0.5 A, commons 8 points 1 common, External connection Removable terminal block, No of words allocated 1 words, current consumption (A) 5 V 0.10     : CJ1W-OD203
- Relay contact output Units, output type sinking, I/O points 16 outputs, Maximum switching capacity 12 to 24 VDC 0.5 A, commons 16 points 1 common, External connection Removable terminal block, No of words allocated 1 words, current consumption (A) 5 V 0.010 : CJ1W-OD211
- Relay contact output Units, output type sinking, I/O points 16 output (High speed), Maximum switching capacity 24 VDC  0.5 A , commons 16 points 1 common, External conetion Removable terminal block, No of words allocated 1 words, current consumption (A) 5 V 0.15   : CJ1W-OD213
- Relay contact output Units, output type sinking, I/O points 32 outputs, Maximum switching capacity 12 to 24 24 VDC 0.5  A, commons 16 points  1 common, External connection Fujitsu connector, No of words allocated 2 words, current consumption (A) 5 V 0.14   : CJ1W-OD231
- Relay contact output Units, output type sinking, I/O points 32 outputs, Maximum switching capacity 12 to 24 VDC 0.5 A, commons 16 points 1 common, External coonection MIL connector, No of words allocated 2 words, current consumption (A) 5 V   : 0.14   : CJ1W-OD233
- RElay contact output Units, output type sinking, I/O points 32 outputs (High speed),  Maximum switching capacity 24 VDC 0.5 A, commons 16 points 1 common, External connection MIL conector, No of words allocaed 2 words, current consumption (A) 5 V 0.22 : CJ1W-OD234
- Relay contact output Units, output type sinking, I/O points 64 outputs, Maximum switching capacity 12 to 24 VDC 0.3 A, commons 16 points 1 common, External connection Fujitsu connector, No of words allocated 4 words, current consumption (A) 5 V 0.17   : CJ1W-OD261
- Relay contac output Units, output type sinking, I/O points 64 outputs, Maximum switching capacity 12 to 24 VDC 0.3 A, commons 16 points 1 common, External connection MIL connector, No of words allocated 4 words, current consumption (A) 5 V 4 words, current consumption (A) 5 V : CJ1W-OD263
- Relay contac output Units, output type sourcing, I/O points 8 outputs, Maximum switching capacity 24 VDC 2 A Shortcircuit protection, commons 4 points 1 common, External connection Removable terminal block, No of words allocated 1 words, current consumption (A) 5 V 0.11 : CJ1W-OD202
- Relay contact output Units, output type sourcing , I/O points 8 outputs, Maximum switching capacity 24 VDC 0.5 A Shortcircuit protection, commons 8 points 1 common, Extenal connection Removable terminal block, No of words allocaed 1 words, current consumpption (A) 5 V 0.10  : CJ1W-OD204
- Relay contact output Units, output type sourcing , I/O points 16 points,Maximum switching capacity 24 VDC 0.5 A Shortcircuit protection, commons 16 points  1 common, External connection Removable terminal block, No of words allocated 1 words, current consumption (A) 5 V 0.10 : CJ1W-OD212
- Relay contac output Units, output type sourcing, I/O points 32 outputs, Maximum switching capacity 24 VDC 0.5 A Shortcircuit protection, commons 16 points 1 common, External connection MIL connector, No of words allocated 2 words, current consumption (A) 5 V  0.15  : CJ1W-OD232
- Relay contact output Units, output type sourcing, I/O points 64 outputs, Maximum switching capacity 12 to 24 VDC 0.3 A, commons 16 points 1 common, External connection MIL connector, No of words allocated 4 words, current consumption (A) 5 V  : CJ1W-OD262


CJ-series Input Units CJ1W-ID / IA : CJ1W-ID201,CJ1W-ID212,CJ1W-ID212,CJ1W-ID231,CJ1W-ID232,CJ1W-ID233, CJ1W-ID261, CJ1W-ID262, CJ1W-IA201, CJ1W-IA111


- CJ1 Basic I/O Units 8 inputs, input voltage and current 12 to 24 VDC 10 mA, Commons Independent contacts , External connection Removable terminal block, No of words allocated 1 word, Current consumption 5 V 0.09 : CJ1W-ID201
- CJ1 Basic I/O Units 16 inputs, inputs voltage and current 24VDC 7 mA, Commons 16 points 1 commons, External connection Removable terminal block, No of words allocated 1 word, current consmption 5 V  0.08   : CJ1W-ID212
- CJ1 Basic I/O Units 16 inputs ( High speed), input voltage and current 24 VDC 4.1 mA, commons i16 points 1 common, External connection Removable terminal block, No of words allocated 1 word, Current consumption 5 V   0.13   : CJ1W-ID212
- CJ1 Basic I/O Units 32 inputs, inputs voltage and current 24 VDC 4.1 mA, Commons 16 points 1 common, External connection Fujitsu connector, No of words allocated 2 words, current consmption 5 V  0.09   : CJ1W-ID231
- CJI Basic I/O Units 32 inputs, input voltage and current 24 VDC 4.1 mA, commons 16 point 1 common, External connection MIL connector, No of words allocated  2 words, current consmption 5 V   0.09   : CJ1W-ID232
- CJ1 Basic I/O Units 32 inputs (High seepd), input voltage and current 24 vdc 4.1 mA, commons 16 points 1 common, External connection MIL connector, No of words allocated 2 words, current consmption 5 V  0.20     : CJ1W-ID233
- CJ1 Basic I/O Units 64 inputs, input voltage and current 24 VDC 4.1 mA, commons Fujitsu connector, No of words allocated 4 words, current consmption 5 V   0.09  : CJ1W-ID261
- CJ1 Basic I/O Units 64 inputs, input voltage and current 24 VDC 4.1 mA, commons 16 points 1 common, Extenal connection MIL connector, No of words allocated 4 words, current consmption  5 V 0.09  : CJ1W-ID262
- CJ1 Basic I/O Units 8 inputs, input voltage and current 200 to 24 VAC 10 mA (200V 50 Hz), commons 8 points 1 common, External connection Removable terminal block, No of words allocated 1 words, current consmption  5 V  0.08  : CJ1W-IA201
- CJ1 Basic Units I/O 16 points, input voltage and current 100 to 120 VAC 7 mA (100 V 50 Hz), commons16 points 1 commonts, External connection Removable terminal block, No of words allocated 1 words, current consmption 5 V   0.09  : CJ1W-IA111

CJ-series Power Supply Unit CJ1W-PA / PD : CJ1W-PA205C,CJ1W-PA205R,CJ1W-PA202,CJ1W-PD025,CJ1W-PD022


- Power supply voltage, 100 to 240 VAC, 5-VDC ouput capacity 5 A, 24-VDC output capacity 0.8 A, Total service power supply No, RUN output No, Maintenance forecast monitor Yes : CJ1W-PA205C
- Power supply voltage 100 to 240 VAC, 5-VDC output capacity 5 A, 24-VDC output capacity 0.8 A, Total power conpsumption25 W, 24-VDC service power supply No, RUN output Yes , Maintenance forcast monitor No : CJ1W-PA205R
- Power supply 100 to 240 VAC, 5-VDC output capacity 2.8 A, 24-VDC outptu capacity 0.4 A,Total power consumption 14 W,  24 service power supply voltage No, RUN capacity No : CJ1W-PA202
- Power supply voltage 24 VDC, 5-VDC output capacity 5A, 24-VDC output capacity 0.8 A, Total power consumpition 25 W, 24-VDC service power supply No, RUN output No, Maintenance forecast monitor No : CJ1W-PD025
- Poower supply voltage 24 VDC, 5-VDC output capacity 2 A, 24-VDC output capacity 0.4 A, 24-VDC output capacity 0.4 A, Total power conusmption 19.6 W , Service power supply No, Maintenance forecast monitor No : CJ1W-PD022

Senin, 24 Juli 2017

Connector Cables for Built-in I/O in CJ1M-CPU2[] CPU Units



- MIL Flat Cable Connectors, 40-pin Pressure-welded Connectors : XG4M-4030-T
- MIL Loose Wire Connectors, 40-pin Crimped Connectors : XG5N-401 *4
- Crimp Contacts for XG5N, LooseContacts Reel : XG5W-0232 , Reel Contacts : XG5W-0232-R
- Manual Crimping Tool For XG5N : XY2B-7007
- Philip Screw (M3 screw terminals, 40-terminals) : XW2R-J40G-T
- Slotted Screw (M3 European type, 40-terminals) : XW2R-E40G-T
- Push-in spring (Clamp 40-terminals) : XW2R-P40G-T
- Cable Leght o,25 m : XW2Z-C25K
- Cable Leght 0,5 m : XW2Z-C50K
- Cble Leght 1 m : XW2Z-100K
- Cable Leght 1,5 m : XW2Z-150K
- Cable leght 2 m : XW2Z-200K
- Cable Leght 3 m : XW2Z-300K
- Cable Leght 5 m : XW2Z-500K
-Servo Relay Unit for 1 axis : XW2B-20J6-8A
- Servo Relay Unit 2 axis : XW2B-40J6-9A
- OMNUC G Series, Cable for CJ1M CPU Unit, Cable Leght 0,5 m : XW2Z-050J-A33 , Cable Leght 1 m : XW2Z-100J-A33
- Servo Driver Connecting Cables, Cable Leght 1 m : XW2Z-100J-B31, Cable Leght 2 : XW2Z-200J-31A
- SMARTSTEP2, Cable for CJ1M CPU Unit , Cable Leght 0,5 : XW2Z-050J-A33
- Cable Driver Connecting Cables , Cable Leght 1 m : XW2Z100-B32, Cable Leght 2 m : XW2Z-200J-B32
- SMARTSTEP2 Junior, Cable for CJ1M CPU Unit, Cable Leght 1 : XW2Z-100J-A26
- Servo Driver Connecting Cables , Cable Laght 1 m : XW2Z-100J-B17, Cable Leght 2 m : XW2Z-200J-B17
- SMARTSTEP A Series, Cable for CJ1M CPU Unit, Cable Leght 1 m : XW2Z-100J-A26
- Servo Driver Connecting Cables, Cable Leght 1 m  : XW2Z-100-B5, Cable Leght 2 m : XW2Z-200J-B5
- OMNUC W Series, Cable CJ1M CPU Unit, Cable Leght 0,5 m : XW2Z-050J-A27,Cable Leght 1 m : XW2Z-100J-A27
-Servo Driver Connecting Cables Cable Leght 1 m : XW2Z-100J-B4, cABLE Leght 2 m : XW2Z-200J-B4

CJ1M CPU Units (with Built-in I/O) : CJ1M-CPU23, CJ1M-CPU22, CJ1M-CPU21


- 640 points/ 20 Units (Expansion Racks max), 20K steps, 10 points and 6 outputs 2 counter inputs, 2 pulse outputs : CJ1M-CPU23
- 320 points/ 10 Units (No Expansion Rack), 10steps : CJ1M-CPU22
- 160 points/ 10 Units (No Expansion Rack), 5K steps : CJ1M-CPU21

SYSMAC CJ-series CJ1M CPU Units (with Ethernet function) : CJ1W-CPU13-ETN,CJ1M-CPU12-ETN,CJ1M-CPU11-ETN


- 640 points/ 20 Units (1 Expansion Rax max), 20 steps, 32K words (DM:32K words EM: None) : CJ1M-CPU13-ETN
- 320 points/ 10 Units (No Expansion Rack), 10 steps : CJ1M-CPU12-ETN
- 160 points/ 10 Units (No Expansion Rack), 5 steps : CJ1M-CPU11-ETN

CJ1M CPU : CJ1M-CPU13,CJ1M-CPU12,CJ1M-CPU11


- 640 I/O points and 20 Unit max (Expansion Rack Max, 20K steps, 32K words DM: 32K :CJ1M-CPU13
- 320 I/O points and 10 Unit max (No Expansion Racks), 10K steps, EM:None : CJ1M-CPU12
- 160 I/O points and 10 Unit max, (No Expansion Racks), 5K steps : CJ1M-CPU11

I/O Modules CQM1H : CQM1-AD041,CQM1-AD041,CQM1-DA022,CQM1-DA021,CQM1-IPS01,CQM1-IPS02,CQM1-B7A02,CQM1-B7A12,CQM1-B7A03,CQM1-B7A13,CQM1-B7A21,CQM1-TC001,CQM1-TC002,CQM1-TC101,CQM1-TC102,CQM1-TC201,CQM1-TC202,CQM1-TC203,CQM1-TC204,CQM1-TC301,CQM1-TC303,CQM1-TC304,CQM1-LSE01,CQM1-LSE02,CQM1-SF200


Analog I/O modules :
- Analog input : 4 point, built bin power supply CQM1-AD042
- Analog inputs 4 point, order separate power ; CQM1-AD041
- Analog outputs 2 point, built in power supply ; CQM1-DA022
- Analog outpu 2 2 point, order separate power supply : CQM1-DA021
- Power supply for one Analog module CQM1-IPS01
- Power supply for two Analog module CQM1-IPS02

B7A Master link modules :
- 16 outputs : CQM1-B7A02
- 16 input : CQM1-B7A12
- 32 outputs : CQM1-B7A03
- 32 inputs : CQM1-B7A13
- 16 inputs and 16 outputs ; CQM1-B7A21

Temperature controller modules :
- Thermocouple input, transistor (PNP) output, 2 loops : CQM1-TC001
- Thermocouple input, transistor (NPN) output, 2 loops : CQM1-TC101
- Platinum resistance thermometer input, transistor (PNP) output, 2 loops : CQM1-TC102
- Thermocouple input, transistor (PNP) output, 4 loops : CQM1-TC202
- Thermocouple input, transistor (NPN) output, 2 loops (with heater burnout alarm) : CQM1-TC203
- Thermocouple input, transistor (PNP) output, 2 loops ( with heater burnout alarm) : CQM1-TC204
- Platinum resistance thermometer input, transistor (NPN) output, 4 loops : CQM1-TC301
- Patinum resistance thermometer input, transistor (PNP) output, 4 loops : CQM1-TC302
- Platinum resistance thermometer input, transistor (NPN) output, 2 loops  : CQM1-TC303
- Platinum resistance thermometer input, transistor (PNP) output, 2 loops : CQM1-TC304

Linear sensor interface modules 
 - Standar : cqm1-lse01:
- With monitor output : CQM1-LSE02

Safety relay module :
- Emergency stop unit : 2 inputs/2 output , 4 general purpose inputs : CQM1-SF200


Communication Modules CQM1 : CQM1H-CLK21, CQM1-SRM21-V1, CQM1-G7M21, CQM1-G7N11, CQM1-G7N01, CQM1-DRT21, CQM1-ARM21


Controller Link Module (wired) : CQM1H-CLK21
CompoBus/S master module : CQM1-SRM21-V1
SYSMAC BUS Modules :
    - Remote master (*use G730 transistor and relay output modules) : CQM1-G7M21
    - Input Expansion : CQM1-G7N11
    - Output Expansion : CQM1-G7N01
  DeviceNet I/O link module : CQM1-DRT21
- AS-interface master module : CQM1-ARM21


Untuk informasi harga dan stock silahkan hubungi marketing kami

Kamis, 20 Juli 2017

Inner Board CQM1H : CQM1IH-CTB41, CQM1H-PLB21,CQM1H-ABB21,CQM1H-AVB41,CQM1H-MAB42,CQM1H-SCB41


High speed counter board : CQM1H-CTB41
Pulse I/O board : CQM1H-PLB21
Absolute encoder interface board : CQM1H-ABB21
Analog setting board : CQM1H-AVB41
Analog I/O board : CQM1H-MAB42
Serial communications board : CQM1H-SCB41

Untuk informasharga dan stock silahkan hubungi marketing kami

Rabu, 19 Juli 2017

Output Modules CQM1 : CQM1-OC221,CQM1-OC222,CQM1-OC224,CQM1-OD211,CQM1-OD212,CQM1-OD213,CQM1-OD215,CQM1-OD214,CQM1-OD216,CQM1-OA221,CQM1-OA222


DC inputs
Contact Output
8 point 250VAC,24VDC Terminal block : CQM1-ID211
16 point 250VAC,24VDC Terminal block CQM1-OC222
8 point 250VAC,24VDC Terminal block CQM1-OC224

Transistor Output
8 point 24VDC Terminal block CQM1-OD211
16 point 24VDC  Terminal block CQM1-OD212
32 point 24VDC Conector CQM1-OD213

Transistor Output
8 point 24VDC Terminal block CQM1-OD215
16 point 24VDC Terminal block CQM1-OD214
32 point 24VDC Connector CQM1-OD216

Triac output
8 point 240VAC Terminal block CQM1-OA221
6 point 240VAC Terminal block CQM1-OA222


Input Modules CQM1H: CQM1-ID211,CQM1-ID111,CQM1-212,CQM1-ID112,CQM1-ID213,CQM1-IA121,CQM1-IA221

DC Inputs :
CQM1-ID211 input 8 point
CQM1-ID111 input 16 point 12VDC
CQM1-ID212 input 16 point 24VDC
CQM1-ID112 input 32 point 12VDC
CQM1-ID213 input 12 point 24VDC


AC Inputs
CQM1-IA121 input 8 point 100 to 120VAC
CQM1-IA221 input 8 point 200 to 240VAC

Untuk informasi harga dan stock silahkan hubungi marketing kami

I/O Expansion and ControlInterface Adapters CQM1H: CQM1H-IC101,CQM1H-II101,CS1W-CN313,CS1W-CN713

I/O Expansion and ControlInterface Adapters CQM1H: CQM1H-IC101,CQM1H-II101,CS1W-CN313,CS1W-CN713


CQM1H-IC101 :







Memory Cassettes CQM1H: CQM1H-ME16K,CQM1H-ME16R,CQM1-ME08K,CQM1H-ME08R,CQM1-ME04K,CQM1-ME04R,CQM1-MP08K,CQM1-MP08R,ROM-ID-B,ROM-JD-B-ROM-KD-KB

Memory Cassettes :
Flash Memory : CQM1H-ME16K , CQM1H-ME16R

EEPROM : CQM1-ME08K, CQM1-ME08R, CQM1-ME04R,CQM1-ME04K

Cassette with IC socket only : CQM1-MP08K , CQM1-MP08R

EPROM chip : ROM-ID-B, ROM-JD-B, ROM-KD-B

SERVO AMPLIFIER MITSUBISHI

Mitsubishi Electric memiliki berbagai seri servo amplifier (juga disebut servo drive) yang dirancang untuk mendukung kontrol gerak presisi t...