CJ1W-TC CJ Series Temperature Control Unit: CJ1W:TC001 * ,CJ1W-TC002 * ,CJ1W-TC003,CJ1W-TC004, CJ1W-TC101*, CJ1W-TC102*, CJ1W-TC103*, CJ1W-TC104


- CJ1 Special I/O Units, Temperature Control Units, No of loops 4 loops, Temperature sensor inputs Thermocouple inputs R S K J T B L, Control outputs Open Collector NPN output (pulses), Unit Numbers allocated 2 , Current consumption (A) 5 V 0.25 : CJ1W:TC001 *
- CJI Special I/O Units, Temperature Control Units, No of loops 4 loops, Temperaturesensor inputs inputs Thermocouple inputs R S K J B L, Control outputs Open Collector PNP outputs (pulses), Unit Numbers allocated 2, Current Consumption (A) 5 V  0.25 : CJ1W-TC002 *
- CJI Special I/O Units, Temperature Control Units, No of loops 2 loops heater burnout detection function, Temperature sensor inputs Thermocouple  inputs R S K J T B L, Control outputs Open Collector NPN output (pulses), Unit Numbers allocated 2, Curren consumption  (A) 5 V 0.25  : CJ1W-TC003
-CJI Special I/O Units, Temperature Control Units, No of loops 2 loops heater burnout detection function, Temperature sensor inputs Thermocouple inputs R S K J T B L, Control outputs Open Collector PNP outputs (pulses), Unit Numbers allocated 2, Current consumption (A) 5 V 0.25 : CJ1W-TC004
- CJI Spesial I/O Units, Temperature Control Units, No of loops 4 loops, Temperature sensor inputs Platinum resistance thermometer input (jPt 100,pt1100), Control outputs Open Collector PNP outputs (pulses), Unit Numbers allocated 2, Current Consumption (A) 5 V 0.025  : CJ1W-TC101*
- CJI Special I/O Unit, Temperature Control Units, No of loops 4 loops, Temperature sensor inputs Platinum resistance thermometer input (jPt 100,pt1100), Control outputs  Open Collector NPN outputs (pulses), Unit Numbers allocated 2 , Current Consumption (A) 5 V 0.25  : CJ1W-TC102*
- CJI Special I/O Unit, Temperature Control Units, No of loops 2 loops heater burnout detection function, Temperature sensor inputs Platinum resistance thermometer input (jPt 100,pt1100), Control outputs Open Collector NPN output (pulses), Unit Numbers allocated 2, Current Consumption (A) 5 V 0.25 : CJ1W-TC103*
- CJI Special I/O Units, Temperature Control Units, No of loops 2 loops heater burnout detection function, Temperature sensor inputs Platinum resistance thermometer input (jPt100,pt11,00), Control outputs Open Collector PNP outputs (pulses), Unit Numbers allocated 2, Current Consumption (A) 5 V 0.25  : CJ1W-TC104