Jual PLC Omron, PLC Mitsubishi, Inverter Omron, HMI Omron, HMI Weintek

PLC , HMI , INVERTER & SERVO : OMRON , MITSUBISHI , WEINTEK / WEINVIEW , DELTA , LS/LG , INVERTER DANFOSS , PRO-FACE , EMERSON , SHIHLIN ELECTRIC , SLANVERT , etc

Gedung LTC-Glodok Lantai 1 Blok B25 No.5 JAKARTA

Alamat Perwakilan Glodok: Gedung LTC-Glodok Lantai 1 Blok B25 No.5 , JAKARTA

Senin, 14 November 2016

Programmable Terminals

OMRON Programmable Terminals are easy-to-use HMIs that provide representational power, network compatibility, and powerful controller linking to support facility and machine production.
OverviewFeatures
PrinciplesClassifications
Engineering DataFurther Information
NS Series Features
This section will describe the features of the NS Series functions.
Smart Ac tie Parts (SAP Library)
SAP is a component that directly accesses the OMRON PLC and components.
Only selecting a required part from the library and putting it on the editing screen enables creating an application that can set up or monitor for the PLC, inverter, servo, communications unit, and temperature controller.
Screens can of course be created, and operation screen, supervision screen, and transmission ladder creation is not required.
Troubleshooting SAP Library
This is the SAP library that performs troubleshooting for each of the OMRON PLC units.
When an error occurs in each unit, the Trouble shooting SAP library inform the cause and countermeasures for the error in an easy-to-understand manner.
Ladder Monitor
Displays a ladder program on the screen, making it possible to see the operating conditions.
The ladder monitor can be used as a PLC electrical monitor, and perform ladder monitoring for address/search commands and multi-point I/O etc.
●Jump from Alarm to Circuit
Automatically search the alarm bit at the flip of a switch or so easily from the alarm screen.
●Reading I/O Comments Directly from PLC, very easily
Read I/O Comments from the PLC with one touch.
No operations are necessary to display I/O Comments.
Integrated Simulation
You can simulate ladder and screen data at the same time on a personal computer without a real PLC nor NS.
Just by clicking one icon, the ladder program and screen can be checked at the same time.
Multi-language Support
42 languages are supported, including a convenient function to change the nameplate.
42 Asian and European languages can be displayed on the screen using Unicode. Also use the nameplate switching function to change nameplates in max. 16 and indicate the language to be displayed on the plate to change one screen in max. 16 languages.
The nameplate encoding can also be set when importing.
When importing screen data, specific encoding can be applied to a nameplate, and the same font and font color can be applied to other name plates automatically.
Multi-language support has become even easier.
You can request translations to a translating companies by simply exporting Japanese screen data to a CS file and emailing it to the company.
Then, by simply importing the translated CS file, the multi-language screens can be easily completed.
Note:For multi-language compatibility, Windows2000 or XP is required.
FTP (File Transfer Protocol)
This is the standard file transfer protocol (procedure) used on the internet.
Since FTP is an (open) protocol, there is a great deal of transmission software (FTP clients) available, and there is also a substantial library available for use with the software.
With the NS, it is possible to transmit screen data to a Windows FTP client, and to create applications that change screen data files with software included in the FTP library.

You can edit text or lists (by Put, Get Commands) from the host computer as well as make changes to recipes so easily!
And you can replace BMP files only such as images and photographs.
Screen changes are also really easy!

Connecting a Computer Running Support Software (e.g., CX-Programmer) to a PLC

Connecting Cables for CJ2
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
USB A plug
connector
(female)
CPU UnitUSB B plug connector
(female)
USB or
Toolbus (USB port)
Commercially available
USB cable * (A plug
connector (male) - B
plug connector (male))
5 m maximumA
D-sub,
9-pin (male)
Built-in RS-232C port
D-sub, 9-pin (female)
Host LinkXW2Z-500S-CV5 mB
XW2Z-200S-CV2 m
*A driver must first be installed to make a USB connection.
Connecting Cables for CS1/CJ1
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin (male)
CPUBuilt-in peripheral
port
Peripheral bus or
Host Link
CS1W-CN2262 mA
CS1W-CN6266 m
CS1W-CN118 + XW2Z-200S-CV0.1 m + 2 mB
CS1W-CN118 + XW2Z-500S-CV0.1m + 5 m
Host LinkCS1W-CN118 + XW2Z-200S-V0.1 m + 2 m
CS1W-CN118 + XW2Z-500S-V0.1 m + 5 m
Host Link with a
baud rate of 19.2
kbps or less
CS1W-CN114 + CQM1-CIF020.05 m
+ 3.3 m
C
Built-in RS-232C port
D-sub, 9-pin (female)
Peripheral bus or
Host Link
XW2Z-200S-CV2 mD
XW2Z-500S-CV5 m
Host LinkXW2Z-200S-V2 m
XW2Z-500S-V5 m
Reference: USB-Serial Conversion Cable (CS1W-CIF31)
ComputerConnecting CableNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portCable port
PC/AT compatibleUSB A plug connector (female)---RS-232C
D-sub, 9-pin (female)
Depends on the Unit's
spcifications.
CS1W-CIF31 *20.5 mA
*1Applicable models: CS/CJ Series, C Series (C200HS, C200HE/G/X, C200H, C1000H, C2000H, CQM1, CPM1, CPM1A, CPM2A, CQM1H, and CPM2C), CVM1/CV Series, NS Series, NT Series, SRM1, and ZEN.
*2.A separate cable is required to connect to the PLC.
Connecting Cables for CP1H/CP1L/CP1E
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
USB A plug
connector
(female)
CPUUSB B plug connector
(female)
USBCommercially available USB
cable (A plug connector (male)
- B plug connector (male))
5 m maximumA
D-sub,
9-pin (male)
RS-232C port (D-sub
9-pin female) on
Option Board *
D-sub, 9-pin (female)
Peripheral bus or
Host Link
XW2Z-200S-CV2 mB
XW2Z-500S-CV5 m
Host LinkXW2Z-200S-V2 m
XW2Z-500S-V5 m
*An Option Board cannot be used with a CP1L CPU Unit with 10 Points and CP1E-E. Also, the CP1E-N and CP1E-NA have a built-in RS-232C port.
Connecting Cables for C200HS/HX/HG/HE
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin (male)
CPUBuilt-in peripheral portPeripheral bus *1 or
Host Link
CQM1-CIF023.3 mA
Built-in RS-232C port
D-sub, 9-pin (female) *2
Host LinkXW2Z-200S-CV2 mB
XW2Z-500S-CV5 m
XW2Z-200S-V2 m
XW2Z-500S-V5 m
Host Link Unit
C200H-LK201-V1
Built-in RS-232C port
D-sub, 25-pin (female)
XW2Z-200P-V *32 mC
XW2Z-500P-V *35 m
*1.These Cables cannot be used for Programming Devices, such as the CX-Programmer, for the C200H-LK201-V1 Host Link Unit on a C200HX/HG/HE-Z PLC.
*2.Only C200HS-CPU21/23/31/33 is equipped with a built-in RS-232C port D-sub, 9-pin (female).
*3.The XW2Z-200S-CV and XW2Z-500S-CV cannot be used.
Connecting Cables for CQM1H
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin
(male)
CPU
*
Built-in peripheral portPeripheral bus or
Host Link
CS1W-CN2262 mA
CS1W-CN6266 m
CS1W-CN114 + CQM1-CIF020.05 m + 3.3 mB
CS1W-CN118 + XW2Z-200S-CV0.1 m + 2 mC
CS1W-CN118 + XW2Z-500S-CV0.1 m + 5 m
CS1W-CN118 + XW2Z-200S-V0.1 m + 2 m
CS1W-CN118 + XW2Z-500S-V0.1 m + 5 m
Built-in RS-232C port
D-sub, 9-pin (female)
Host LinkXW2Z-200S-CV2 mD
XW2Z-500S-CV5 m
XW2Z-200S-V2 m
XW2Z-500S-V5 m
*Discontinuation models in March 2012.
Connecting Cables for CQM1
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin (male)
CPU
*
Built-in peripheral portPeripheral bus or Host LinkCQM1-CIF023.3 mA
Built-in RS-232C port
D-sub, 9-pin (female)
(CPU42/43/44/63/64/65/85 only)
Host LinkXW2Z-200S-CV2 mB
XW2Z-500S-CV5 m
XW2Z-200S-V2 m
XW2Z-500S-V5 m
*Discontinuation models in March 2001.
Connecting Cables for CPM1, CPM1A and CPM2A
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin (male)
CPU UnitBuilt-in peripheral portPeripheral bus * or
Host Link
CQM1-CIF023.3 mA
CPM1-CIF01 + XW2Z-200S-CV2 mB
CPM1-CIF01 + XW2Z-500S-CV5 m
Host LinkCPM1-CIF01 + XW2Z-200S-V2 m
CPM1-CIF01 + XW2Z-500S-V5 m
*CPM2A CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) do not support Toolbus connections. They do support Host Link connections.
Connecting Cables for SRM1
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin (male)
CPU UnitBuilt-in peripheral portPeripheral bus or
Host Link
CQM1-CIF023.3 mA
CPM1-CIF01 + XW2Z-200S-CV2 mB
CPM1-CIF01 + XW2Z-500S-CV5 m
Host LinkCPM1-CIF01 + XW2Z-200S-V2 m
CPM1-CIF01 + XW2Z-500S-V5 m
Built-in RS-232C port
D-sub, 9-pin (female)
(SRM1-C01 only)
XW2Z-200S-CV2 mC
XW2Z-500S-CV5 m
XW2Z-200S-V2 m
XW2Z-500S-V5 m
Connecting Cables for CPM2C
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin
(male)
CPUCommunications
port (as a
peripheral port)
Peripheral bus *1 or
Host Link
CS1W-CN226 *22 mA
CS1W-CN626 *26 m
CS1W-CN114 + CQM1-CIF020.05 m + 3.3 mB
CPM2C-CIF01-V1 + CS1W-CN114
+ CQM1-CIF02
Adapter + 0.05 m
+ 3.3 m
C
CPM2C-CN111 (Peripheral port)
+ CQM1-CIF02
0.1 m + 3.3 mD
Communications
port (as an
RS-232C port)
Host LinkCS1W-CN118 + XW2Z-200S-CV0.1 m + 2 mE
CS1W-CN118 + XW2Z-500S-CV0.1 m + 5 m
CS1W-CN118 + XW2Z-200S-V0.1 m + 2 m
CS1W-CN118 + XW2Z-500S-V0.1 m + 5 m
CPM2C-CN111 (RS-232C port)
+ XW2Z-200S-CV
0.1m + 2mF
CPM2C-CN111 (RS-232C port)
+ XW2Z-500S-CV
0.1 m + 5 m
CPM2C-CN111 (RS-232C port)
+ XW2Z-200S-V
0.1 m + 2 m
CPM2C-CN111 (RS-232C port)
+ XW2Z-500S-V
0.1 m + 5 m
CPM2C-CIF01-V1 + XW2Z-200S-CVAdapter + 2 mG
CPM2C-CIF01-V1 + XW2Z-500S-CVAdapter + 5 m
CPM2C-CIF01-V1 + XW2Z-200S-VAdapter + 2 m
CPM2C-CIF01-V1 + XW2Z-500S-VAdapter + 5 m
CPM2C-CIF01-V1 + CS1W-CN118
+ XW2Z-200S-CV
Adapter + 0.1 m
+ 2 m
H
CPM2C-CIF01-V1 + CS1W-CN118
+ XW2Z-500S-CV
Adapter + 0.1 m
+ 5 m
CPM2C-CIF01-V1 + CS1W-CN118
+ XW2Z-200S-V
Adapter + 0.1 m
+ 2 m
CPM2C-CIF01-V1 + CS1W-CN118
+ XW2Z-500S-V
Adapter + 0.1 m
+ 5 m
CPM2C-CIF11 + XW2Z-200S-VAdapter + 2 mI
CPM2C-CIF11 + XW2Z-500S-VAdapter + 5 m
CPM2C-CIF21 + XW2Z-200S-VAdapter + 2 m
CPM2C-CIF21 + XW2Z-500S-VAdapter + 5 m
*1.CPM2C CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) and that were manufactured in 1999 do not support Toolbus connections. They do support Host Link connections.
*2.Only Host Link (SYSMAC WAY) connections are possible. Toolbus cannot be used.
Connecting Cables for C1000H, C2000H, C200H
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin
(male)
CPU UnitBuilt-in peripheral
port
Host LinkC200H-IP007 + CQM1-CIF02 *3.3 mA
Host Link Unit
C1000H, C2000H:
C500-LK203
C500-LK201-V1
(3G2A5-LK201-V1)
C120-LK201-V1
(3G2A6-LK201-EV1)
C200H:
C200H-LK201-V1
C120-LK201-V1
(3G2A6-LK201-EV1)
Built-in RS-232C
port
D-sub, 25-pin
(female)
XW2Z-200P-V2 mB
XW2Z-500P-V5 m
*Connection cannot be made from the CQM1-CIF02 directly to a computer for the C200H Handheld Programming Console connecting cable. Use the C200H-IP007.
Connecting Cables for CVM1/CV
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT compatibleD-sub,
9-pin (male)
CPU Unit *1Built-in peripheral portHost LinkCV500-CIF01 *26 mA
Built-in RS-232C port
D-sub, 9-pin (female)
XW2Z-200S-V *32 mB
XW2Z-500S-V *35 m
Host Link Unit
CV500-LK201 *1
(for full duplex
communication
on port 1)
Built-in RS-232C port
D-sub, 25-pin (female)
XW2Z-200P-V *32 mC
XW2Z-500P-V *35 m
Host Link Unit
CV500-LK201 *1
(for full duplex
communication
on port 2)
Built-in RS-232C port
D-sub, 9-pin (female)
XW2Z-200S-V *32 mD
XW2Z-500S-V *35 m
*1.Discontinuation models in March 2012.
*2.A commercially available 25-pin/9-pin straight conversion cable is separately required.
*3.The XW2Z-200S-CV and XW2Z-500S-CV cannot be used.
Connecting Cables for C500
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin
(male)
CPU Unit *1Built-in peripheral
port
Host LinkC200H-IP007 + CQM1-CIF023.3 mA
Host Link Unit *2
C500-LK203
C500-LK201-V1
(3G2A5-LK201-EV1)
C120-LK201-V1
(3G2A6-LK201-EV1)
Built-in RS-232C
port
D-sub, 25-pin
(female)
XW2Z-200P-V2 mB
XW2Z-500P-V5 m
*1.Production of the CPU Units was discontinued in March 2004.
*2.Production of the C500-LK203, C500-LK201-V1 (3G2A5-LK201-EV1), and C120-LK201-V1 (3G2A6-LK201-EV1) was discontinued in March 2006. (There is no recommended substitute product.)
Connecting Cables for C120
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin
(male)
CPU Unit *1Built-in peripheral
port
Host LinkC200H-IP007 + CQM1-CIF023.3 mA
Host Link Unit *2
C120-LK201-V1
(3G2A6-LK201-EV1)
Built-in RS-232C
port
D-sub, 25-pin
(female)
XW2Z-200P-V2 mB
XW2Z-500P-V5 m
*1.Production of the CPU Units was discontinued in March 2003.
*2.Production of the C120-LK201-V1 was discontinued in March 2006. (There is no recommended substitute product.)
Connecting Cables for C20P/C28P/C40P/C60P*1, C20K/C28K/C40K/C60K*2
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
D-sub,
9-pin (male)
Host Link Unit *3 *4
C20-LK201-V1
(3G2C7-LK201-EV1)
Built-in RS-232C port
D-sub, 25-pin (female)
Host LinkXW2Z-200P-V2 mA
XW2Z-500P-V5 m
*1.Production of the C20P, C28P, C40P, and C60P CPU Units was discontinued in March 2002.
*2.Production of the C20K, C28K, C40K, and C60K CPU Units was discontinued in March 2002.
*3.For connection to C[][]P PLCs, a Host Link Unit is also required in addition to a Connecting Cable.
*4.Production of the C20-LK201-V1 (3G2C7-LK201-EV1) was discontinued in March 2006. (There is no recommended substitute product.)
Connecting Cables for NSJ
ComputerUnitNetwork Type
(Serial
Communications
Mode)
ModelCable
length
Con-
nection
Types
PC portUnit port
PC/AT
compatible
USB A plug
connector
(male)
CPUUSB B plug connector
(female)
USBCommercially available USB
cable (A plug connector (male)
- B plug connector (male))
5 m maximumA
D-sub,
9-pin (male)
Built-in RS-232C port
D-sub, 9-pin (female)
Peripheral bus or
Host Link
XW2Z-200S-CV2 mB
XW2Z-500S-CV5 m
Host LinkXW2Z-200S-V2 m
XW2Z-500S-V5 m