Jual FX3S PLC Mitsubishi Melsec FX Series

FX3S PLC Mitsubishi Melsec F Series

FX3S - Keeping it Simple
 
Controllable I/O : 10 - 30 points
Main Unit I/O : 10/14/20/30 points
Fast Instruction Times

Basic Instructions : 0.21µs / Instruction (COntact Instruction)
Applied Instructions : 0.5µs / Instruction (MOV Instruction)
 
Large Memory
4000 steps of built-in program memory. No battery, no maintenance.
Large Device Memory
  • Auxiliary Relays : 1,536 points
  • Timers : 138 points
  • Counters : 88 points
  • Data Registers : 3,000 points

FX3S Main Units with 10 I/O

FX3S-10MR/DS : 24 VDC
FX3S-10MR/ES : 100-240 VAC
FX3S-10MT/DS : 24 VDC
FX3S-10MT/DSS : 24 VDC
FX3S-10MT/ES : 100-240 VAC
FX3S-10MT/ESS : 100-240 VAC

 
FX3S Main Units with 14 I/O

FX3S-14MR/DS : 24 VDC
FX3S-14MR/ES : 100-240 VAC
FX3S-14MT/DS : 24 VDC
FX3S-30MT/DSS : 24 VDC
FX3S-14MT/ES : 100-240 VAC
FX3S-14MT/ESS : 100-240 VAC

 
FX3S Main Units with 20 I/O

FX3S-20MR/DS : 24 VDC
FX3S-20MR/ES : 100-240 VAC
FX3S-20MT/DS : 24 VDC
FX3S-20MT/DSS : 24 VDC
FX3S-20MT/ES : 100-240 VAC
FX3S-20MT/ESS : 100-240 VAC
FX3S Main Units with 30 I/O

FX3S-30MR/DS : 24 VDC
FX3S-30MR/ES : 100-240 VAC
FX3S-30MT/DS : 24 VDC
FX3S-30MT/DSS : 24 VDC
FX3S-30MT/ES : 100-240 VAC
FX3S-30MT/ESS : 100-240 VAC
FX3S Main Units with 30 I/O and Analog Inputs

FX3S-30MR/ES-2AD : 100-240 VAC
FX3S-30MT/ES-2AD : 100-240 VAC
FX3S-30MT/ESS-2AD : 100-240 VAC
FX3S Feature
  • High performance with minimal size
  • Integrated power supply (AC powered)
  • Maintenance-free EEPROM memory
  • Ample memory capacity (4000 steps) and device ranges
  • Built-in USB port for the programming communication function to enable high-speed communication at 12Mbps
  • Built-in positioning control
  • Integrated real-time clock
  • Increased functionality using Expansion Boards and Special Adapters
  • Programming with GX Works2 or GX Works2 FX

FX3S Main Units with 10 I/O

Model Number
FX3S-10MR/DS
FX3S-10MR/ES
FX3S-10MT/DS
FX3S-10MT/DSS
FX3S-10MT/ES
FX3S-10MT/ESS
Stocked Item
S
S
S
S
S
S
Rating
UL • cUL • CE (EMC)
Integrated Inputs/Outputs
10
10
10
10
10
10
Power Supply (V)
24VDC
100 - 240VAC
24VDC
24VDC
100 - 240VAC
100 - 240VAC
Integrated Inputs
6
6
6
6
6
6
Integrated Outputs
4
4
4
4
4
4
Output Type
Relay
Relay
Transistor (Sink)
Transistor (Source)
Transistor (Sink)
Transistor (Source)
Power Consumption (W)
6
19
6
6
19
19
Weight (kg)
0.22
0.3
0.22
0.22
0.3
0.3
Dimensions (W x H x D) mm
60 x 90 x 75
60 x 90 x 75
60 x 90 x 49
60 x 90 x 49
60 x 90 x75
60 x 90 x75

FX3S Main Units with 14 I/O

Model Number
FX3S-14MR/DS
FX3S-14MR/ES
FX3S-14MT/DS
FX3S-30MT/DSS
FX3S-14MT/ES
FX3S-14MT/ESS
Stocked Item
S
S
-
S
S
S
Rating
UL • cUL • CE (EMC)
Integrated Inputs/Outputs
10
14
14
14
14
14
Power Supply (V)
24VDC
100 - 240VAC
24VDC
24VDC
100 - 240VAC
100 - 240VAC
Integrated Inputs
8
8
8
8
8
8
Integrated Outputs
6
6
6
6
6
6
Output Type
Relay
Relay
Transistor (Sink)
Transistor (Source)
Transistor (Sink)
Transistor (Source)
Power Consumption (W)
6.5
19
6.5
6.5
19
19
Weight (kg)
0.22
0.3
0.22
0.22
0.3
0.3
Dimensions (W x H x D) mm
60 x 90 x 49
60 x 90 x75
60 x 90 x 49
60 x 90 x 49
60 x 90 x 75
60 x 90 x 75

FX3S Main Units with 20 I/O

Model Number
FX3S-20MR/DS
FX3S-20MR/ES
FX3S-20MT/DS
FX3S-20MT/DSS
FX3S-20MT/ES
FX3S-20MT/ESS
Stocked Item
S
S
-
S
S
S
Rating
UL • cUL • CE (EMC)
Integrated Inputs/Outputs
20
20
20
20
20
20
Power Supply (V)
24VDC
100 - 240VAC
24VDC
24VDC
100 - 240VAC
100 - 240VAC
Integrated Inputs
12
12
12
12
12
12
Integrated Outputs
8
8
8
8
8
8
Output Type
Relay
Relay
Transistor (Sink)
Transistor (Source)
Transistor (Sink)
Transistor (Source)
Power Consumption (W)
7
20
7
7
20
20
Weight (kg)
0.3
0.4
0.3
0.3
0.4
0.4
Dimensions (W x H x D) mm
75 x 90 x 49
75 x 90 x 75
75 x 90 x 49
75 x 90 x 49
75 x 90 x 75
75 x 90 x 75

FX3S Main Units with 30 I/O

Model Number
FX3S-30MR/DS
FX3S-30MR/ES
FX3S-30MT/DS
FX3S-30MT/DSS
FX3S-30MT/ES
FX3S-30MT/ESS
Stocked Item
S
S
-
S
S
S
Rating
UL • cUL • CE (EMC)
Integrated Inputs/Outputs
30
30
30
30
30
30
Power Supply (V)
24VDC
100 - 240VAC
24VDC
24VDC
100 - 240VAC
100 - 240VAC
Integrated Inputs
16
16
16
16
16
16
Integrated Outputs
14
14
14
14
14
14
Output Type
Relay
Relay
Transistor (Sink)
Transistor (Source)
Transistor (Sink)
Transistor (Source)
Power Consumption (W)
8.5
21
8.5
8.5
21
21
Weight (kg)
0.35
0.45
0.35
0.35
0.45
0.45
Dimensions (W x H x D) mm
100 x 90 x 49
100 x 90 x 75
100 x 90 x 49
100 x 90 x 49
100 x 90 x 75
100 x 90 x 75

FX3S Main Units with 30 I/O and Analog Inputs

Model Number
FX3S-30MR/ES-2AD
FX3S-30MT/ES-2AD
FX3S-30MT/ESS-2AD
Stocked Item
S
S
S
Rating
UL • cUL • CE (EMC)
Integrated Inputs/Outputs
30
30
30
Power Supply (V)
100 - 240VAC
100 - 240VAC
100 - 240VAC
Integrated Digital Inputs
16
16
16
Integrated Analog Inputs
2 (10 bit, 0-10VDC)
2 (10 bit, 0-0VDC)
2 (10 bit, 0-10VDC)
Integrated Outputs
14
14
14
Output Type
Relay
Transistor (Source)
Transistor (Sink)
Power Consumption (W)
21
21
21
Weight (kg)
0.45
0.45
0.45
Dimensions (W x H x D) mm
100 x 90 x 49
100 x 90 x 75
100 x 90 x 75


Jual Mitsubishi PLC FX1S-30M


Mitsubishi PLC Tipe FX1S-30M
  1. Mitsubishi FX1S-30MT-DSS
  2. Mitsubishi FX1S-30MR-DS
  3. Mitsubishi FX1S-30MR-ES/UL

Spesifikasi Mitsubishi PLC Tipe FX1S-30M


FX1S-30MT-DSSFX1S-30MR-DSFX1S-30MR-ES/UL
Part NumberFX1S-30MT-DSSFX1S-30MR-DSFX1S-30MR-ES/UL
SeriesFX1SFX1SFX1S
ManufacturerMitsubishiMitsubishiMitsubishi
Our part numberFX1S30MTDSSFX1S30MRDSFX1S30MRES/UL
Inputs amount161616
Inputs type24 VDC Sink/Source24 VDC Sink/Source100-240 VAC
Outputs typeTransistor (source)RelayRelay
Voltage12-24 VDC24 VDC100-240 VAC
Height (mm)909090
Width (mm)100100100
Depth (mm)494975
Weight (kg)0.350.350.45

Information Product Mitsubishi PLC Tipe FX1S-14M
  • Available as AC or DC powered
  • Available with 10-30 inputs/outputs
  • Available with relay or transistor outputs
  • High speed inputs for fast counting tasks
  • LEDs for indicating input & output status
  • Two analogue potentiometers & a run/stop switch
  • Integrated RS422 serial interface
  • Can be mounted on DIN rail or a flat surface
  • Password access protection
  • 2,000 step program EEPROM memory
  • Incorporated positioning control
  • Integrated real time clock
  • Two integrated high speed pulse outputs
  • Square pulse output on transistor models
  • Internal service 24 VDC power supply on AC models
  • User friendly programming systems

Jual Mitsubishi PLC FX1S-20M Seri




Mitsubishi PLC Tipe FX1S-20M
  1. Mitsubishi FX1S-20MT-DSS
  2. Mitsubishi FX1S-20MR-DS
  3. Mitsubishi FX1S-20MR-ES

Spesifikasi Mitsubishi PLC Tipe FX1S-20M


FX1S-20MT-DSSFX1S-20MR-DSFX1S-20MR-ES
Part NumberFX1S-20MT-DSSFX1S-20MR-DSFX1S-20MR-ES
SeriesFX1SFX1SFX1S
ManufacturerMitsubishiMitsubishiMitsubishi
Our part numberFX1S20MTDSSFX1S20MRDSFX1S20MRES/UL
Inputs amount121212
Inputs type24 VDC Sink/Source24 VDC Sink/Source100-240 VAC
Outputs amount888
Outputs typeTransistor (source)RelayRelay
Voltage24 VDC24 VDC100-240 VAC
Height (mm)909090
Width (mm)757575
Depth (mm)494975
Weight (kg)0.30.30.4

Information Product Mitsubishi PLC Tipe FX1S-20M
  • Available as AC or DC powered
  • Available with 10-30 inputs/outputs
  • Available with relay or transistor outputs
  • High speed inputs for fast counting tasks
  • LEDs for indicating input & output status
  • Two analogue potentiometers & a run/stop switch
  • Integrated RS422 serial interface
  • Can be mounted on DIN rail or a flat surface
  • Password access protection
  • 2,000 step program EEPROM memory
  • Incorporated positioning control
  • Integrated real time clock
  • Two integrated high speed pulse outputs
  • Square pulse output on transistor models
  • Internal service 24 VDC power supply on AC models
  • User friendly programming systems

Jual Power Supply Unit CJ-series





CJ1W-PA/PD

Equipped with the RUN output for checking the operation status, as well as the replacement notification function for easy maintenance. Lineup of five models including the AC power supply (25W).

The replacement notification function can prevent an overflow of the system due to the power lifetime. (CJ1W-PA205C only)

Power Supply Unit provides wide variations according to the system scale up to maximum 25 W.

Power Supply Unit provides wide variations according to the power supply (100 to 240 V AC/ 24 V DC) status.

The output contact during operation enables you to check the CPU operation. (CJ1W-PA205R only)

Conforming to the SEMI-F47 Standard. *

*AC input type, 200 V min. input.

Specifications :

ItemSpecifications
ModelCJ1W-PA205RCJ1W-PA205CCJ1W-PA202
Supply voltage100 to 240 V AC (wide-range), 50/60 Hz
Operating voltage and
frequency ranges
85 to 264 V AC, 47 to 63 Hz
Power consumption100 VA max.50 VA max.
Inrush current *1At 100 to 120 V AC: 15 A/8 ms max. for cold start at room temperature
At 200 to 240 V AC: 30 A/8 ms max. for cold start at room temperature
At 100 to 120 V AC:
20 A/8 ms max. for cold start at
room temperature
At 200 to 240 V AC:
40 A/8 ms max. for cold start at
room temperature
Output capacity *75.0 A, 5 V DC (including supply to CPU Unit)2.8 A, 5 V DC
(including supply to CPU Unit)
0.8 A, 24 V DC0.4 A, 24 V DC
Total: 25 W max.Total: 14 W max.
Output terminal
(service supply)
Not provided.
RUN output *2Contact configuration: SPST-NO
Switch capacity:
250 V AC, 2 A (resistive load)
120 V AC, 0.5 A (inductive load),
24 V DC, 2A (resistive load)
24 V DC, 2 A (inductive load)
Not provided.
Replacement
notification function
Not provided.With Alarm output (open-collector
output)
30 V DC max., 50 mA max.
Not provided.
Insulation resistance20 MΩ min. (at 500 V DC) between
AC external and GR terminals *3
20 MΩ min. (at 500 V DC) between
all external terminals and GR
terminal *3, and between all alarm
output terminals.
20 MΩ 1 min. (at 250 V DC)
between all alarm output terminals
and GR terminal *3.
20 MΩ min. (at 500 V DC) between
AC external and GR terminals *3
Dielectric strength *42,300 V AC 50/60 Hz for 1 min
between AC external and GR
terminals *3
Leakage current: 10 mA max.
2,300 VAC, 50/60 Hz for 1 min
between all external terminals and
GR terminal *3 and between all
alarm output terminals with a
leakage current of 10 mA max.
1,000 V AC, 50/60 Hz for 1 min
between all alarm output terminals
and GR terminal *3 with a leakage
current of 10 mA max.
2,300 V AC 50/60 Hz for 1 min
between AC external and GR
terminals *3
Leakage current: 10 mA max.
1,000 V AC, 50/60 Hz for 1 minute between DC external and GR terminals *3
Leakage current: 10 mA max.
Noise immunity2 kV on power supply line (conforming to IEC61000-4-4)
Vibration resistanceConforms to IEC60068-2-6
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min)
Shock resistanceConforms to IEC60068-2-27
147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
Ambient operating
temperature
0 to 55 ° C
Ambient operating
humidity
10% to 90% (with no condensation)10% to 90% (with no condensation) *510% to 90% (with no condensation)
AtmosphereMust be free from corrosive gases.
Ambient storage
temperature
- 20 to 70 ° C (excluding battery)- 20 to 75 ° C *5- 20 to 75 ° C (excluding battery)
GroundingLess than 100 Ω
EnclosureMounted in a panel.
WeightAll models are each 5 kg max.
CPU Rack dimensions90.7 to 466.7 × 90 × 65 mm (W × H × D) (not including cables)
Note:
W = a + b + 20 × n + 31 × m + 14.7
a: Power Supply Unit: PA205R and PA205C = 80; PA202 = 45; PD025 = 60; PD022=27
b: CPU Unit: CJ1-H or CJ1 = 62; CJ1M-CPU1[] = 31; CJ1M-CPU2[] = 49
The total width is given by the following: W = 156.7 + n × 20 + m × 31, where n is the number of 32-point I/O Units
or I/O Control Units and m is the number of other Units.
Safety measuresConforms to cULus and EC Directives.

Item
Power Supply Unit
Specifications
CJ1W-PD025CJ1W-PD022
Supply voltage24 VDC
Operating voltage and
frequency ranges
19.2 to 28.8 V DC21.6 to 26.4 V DC
Power consumption50 W max.35 W max.
Inrush current *1At 24 V DC: 30 A/20 ms max. for cold start
Output capacity *75.0 A, 5 V DC (including supply to CPU Unit)2.0 A, 5 V DC (including supply to CPU Unit)
0.8 A, 24 V DC0.4 A, 24 V DC
Total: 25 W max.Total: 19.6 W max.
Output terminal
(service supply)
Not provided.
RUN output *2Not provided.
Replacement
notification function
Not provided.
Insulation resistance20 MΩ min. (at 500 V DC) between DC external
and GR terminals *3
---
*6
Dielectric strength *41,000 V AC, 50/60 Hz for 1 min between DC
external and GR terminals *3
Leakage current: 10 mA max.
---
*6
Noise immunity2 kV on power supply line (conforming to IEC61000-4-4)
Vibration resistanceConforms to IEC60068-2-6
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min)
Shock resistanceConforms to IEC60068-2-27
147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
Ambient operating
temperature
0 to 55 ° C
Ambient operating
humidity
10% to 90% (with no condensation)
AtmosphereMust be free from corrosive gases.
Ambient storage
temperature
- 20 to 75 ° C (excluding battery)
GroundingLess than 100 Ω
EnclosureMounted in a panel.
WeightAll models are each 5 kg max.
CPU Rack dimensions90.7 to 466.7 × 90 × 65 mm (W × H × D) (not including cables)
Note:
W = a + b + 20 × n + 31 × m + 14.7
a: Power Supply Unit: PA205R and PA205C = 80; PA202 = 45; PD025 = 60; PD022=27
b: CPU Unit: CJ1-H or CJ1 = 62; CJ1M-CPU1[] = 31; CJ1M-CPU2[] = 49
The total width is given by the following: W = 156.7 + n × 20 + m × 31, where n is the number of 32-point I/O Units
or I/O Control Units and m is the number of other Units.
Safety measuresConforms to cULus and EC Directives.

*1.Disconnect the Power Supply Units LG terminal from the GR terminal when testing insulation and dielectric strength. Testing the insulation and dielectric strength with the LG terminal and the GR terminals connected will damage internal circuits in the CPU Unit.

*2.Supported only when mounted to CPU Rack.

*3.The inrush current is given for a cold start at room temperature. The inrush control circuit uses a thermistor element with a low-temperature current control characteristic. If the ambient temperature is high or the PLC is hot-started, the thermistor will not be sufficiently cool, and the inrush currents given in the table may be exceeded by up to twice the given values. When selecting fuses or breakers for external circuits, allow sufficient margin in shut-off performance.

*4.Maintain an ambient storage temperature of −25 to 30°C and relative humidity of 25% to 70% when storing the Unit for longer than 3 months to keep the replacement notification function in optimum working condition.

*5.Change the applied voltage gradually using the adjuster on the Tester. If the full dielectric strength voltage is applied or turned OFF using the switch on the Tester, the generated impulse voltage may damage the Power Supply Unit.

*6.CJ1W-PD022 is not insulated between the primary DC power and secondary DC power.

*7.Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an extended period of time exceeding the power supply output capacity or if the outputs are shorted.

Checking Current Consumption and Power Consumption

After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for each Rack.

Condition 1: Current Requirements

There are two voltage groups for internal power consumption: 5 V and 24 V.
Current consumption at 5 V (internal logic power supply)
Current consumption at 24 V (relay driving power supply)

Condition 2: Power Requirements

For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current supplied for the voltage groups shown in the following tables.
The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are shown below.

Note:

1.For CPU Racks, include the CPU Unit current and power consumption in the calculations. When expanding, also include the current and power consumption of the I/O Control Unit in the calculations.

2.For Expansion Racks, include the I/O Interface Unit current and power consumption in the calculations.

Power Supply UnitsMax. current suppliedMax. total power supplied
5 V24 V (relay driving current)
CJ1W-PA205R5.0 A0.8 A25 W
CJ1W-PA205C5.0 A0.8 A25 W
CJ1W-PA2022.8 A0.4 A14 W
CJ1W-PD0255.0 A0.8 A25 W
CJ1W-PD0222.0 A0.4 A19.6 W

Conditions 1 and 2 below must be satisfied.

Condition 1: Maximum Current

(1)Total Unit current consumption at 5 V ≤ (A) value

(2)Total Unit current consumption at 24 V ≤ (B) value

Condition 2: Maximum Power

(1) × 5 V + (2) × 24 V ≤ (C) value

Example: Calculating Total Current and Power Consumption

Example: When the Following Units are Mounted to a CJ-series CPU Rack Using a CJ1W-PA202 Power Supply Unit

Unit typeModelQuantityVoltage group
5 V24 V
CPU UnitCJ1G-CPU45H10.910 A---
I/O Control UnitCJ1W-IC10110.020 A---
Basic I/O Units
(Input Units)
CJ1W-ID21120.080 A---
CJ1W-ID23120.090 A---
Basic I/O Units
(Output Units)
CJ1W-OC20120.090 A0.048 A
Special I/O UnitCJ1W-DA04110.120 A---
CPU Bus UnitCJ1W-CLK2310.350 A---
Current consumptionTotal0.910 + 0.020 + 0.080 × 2 + 0.090 ×
2 + 0.090 × 2 + 0.120 + 0.350
0.048 A × 2
Result1.92 A ( ≤ 2.8 A)0.096 A ( ≤ 0.4 A)
Power consumptionTotal1.92 × 5 V = 9.60 W0.096 A × 24 V = 2.304 W
Result9.60 + 2.304 Power_Supply_Unit_CJ-series.jpg 11.904 W ( ≤ 14 W)

Jual Mitsubishi Compact PLC Melsec FX1N Seri








Mitsubishi Compact PLC Melsec FX1N ini tersedia dalam beberapa tipe, yaitu :
  • Tipe FX1N-14
  • Tipe FX1N-24
  • Tipe FX1N-40
  • Tipe FX1N-60

Mitsubishi Compact PLC Melsec FX1N menggabungkan manfaat dari kontroler kompak dengan kemampuan ekspansi yang fleksibel dari sistem kontrol modular. Hal ini dapat diperluas hingga 128 input dan output dan dengan berbagai komprehensif modul fungsi khusus. Mitsubishi Compact PLC Melsec FX1N ini juga dilengkapi dengan pengontrol posisi kuat terintegrasi.

Kemampuan komunikasi dan kemampuan data link membuatnya ideal untuk aplikasi di mana ukuran controller hardware, fitur komunikasi, fungsi khusus dan kecepatan pemrosesan semua penting.

Mitsubishi Compact PLC Melsec FX1N highlights:
  • 14 to 128 inputs and outputs
  • High processing speed ( 0.55µ s per log. instruction)
  • Ample program storage capacity ( 8, 000 steps) and device ranges
  • Integrated positioning controller
  • Comprehensive range of special function and expansion modules for individual requirements
  • Integrated PID controller
  • Support for connection to open networks
  • Integrated real-time clock
  • User-friendly programming with MS Windows-based programming software package or hand-held programming unit
  • Analog signal processing with optional expansion adapters

Spesifikasi Mitsubishi Compact PLC Melsec FX1N :

TypeFX1N-14FX1N-24FX1N-40FX1N-60
Power supply100-240 V AC/ 12-24 V DC
No. of inputs8142436
No. of outputs6101624
Digital outputsRelay / Transistor
Program cycle period per logical instruction0.55 -1 µs
User memory8.000 steps EEPROM (internal), EEPROM/ EPROM cassettes (optional)
Dimensions in mm (WxHxD)90 x 90 x 7590 x 90 x 75175 x 90 x 75185 x 90 x 75

Jual Mitsubishi Compact PLC Melsec FX1S Seri








Mitsubishi Compact PLC Melsec FX1S ini tersedia dalam beberapa tipe, yaitu :
    1. Tipe FX1S-10M
      1. Mitsubishi FX1S-10MT-DSS
      2. Mitsubishi FX1S-10MR-DS
      3. Mitsubishi FX1S-10MR-ES/UL
    2. Tipe FX1S-14M
      1. Mitsubishi FX1S-14MR-DS
      2. Mitsubishi FX1S-14MT-DSS
      3. Mitsubishi FX1S-14MR-ES/UL
    3. Tipe FX1S-20M
      1. Mitsubishi FX1S-20MT-DSS
      2. Mitsubishi FX1S-20MR-DS
      3. Mitsubishi FX1S-20MR-ES/UL
    4. Tipe FX1S-30M
      1. Mitsubishi FX1S-30MT-DSS
      2. Mitsubishi FX1S-30MR-DS
      3. Mitsubishi FX1S-30MR-ES/UL

      Controller dari seri Mitsubishi Compact PLC Melsec FX1S series memberikan fungsi yang luar biasa sampai dengan I/O 30  dalam paket yang sangat kompak. Mitsubishi Compact PLC Melsec FX1S series sangat ideal untuk aplikasi sulit untuk akses instalasi dan sistem di mana pelayanan yang normal tidak mungkin. real-time terintegrasi dan bebas perawatan EEPROM dengan kapasitas hingga 2.000 langkah program yang membuat FX1S menyediakan sistem otonom dan pelayanan yang sangat mudah.

      Mitsubishi Compact PLC Melsec FX1S series highlights:
      • 10 to 30 inputs and outputs
      • High processing speed ( 0.55? s per log. instruction)
      • Ample program storage space and large device ranges Integrated positioning controller
      • Serial communications options ( RS-232, RD-422, RS-485)
      • Analog signal processing with optional expansion adapters
      • Integrated real-time clock
      • User-friendly programming with MS Windows-based programming software package or hand-held programming unit
      • Expandable with adapters or display modules

      Information Product
      • Available as AC or DC powered
      • Available with 10-30 inputs/outputs
      • Available with relay or transistor outputs
      • High speed inputs for fast counting tasks
      • LEDs for indicating input & output status
      • Two analogue potentiometers & a run/stop switch
      • Integrated RS422 serial interface
      • Can be mounted on DIN rail or a flat surface
      • Password access protection
      • 2,000 step program EEPROM memory
      • Incorporated positioning control
      • Integrated real time clock
      • Two integrated high speed pulse outputs
      • Square pulse output on transistor models
      • Internal service 24 VDC power supply on AC models
      • User friendly programming systems

      Spesifikasi Mitsubishi Compact PLC Melsec FX1S :

      TypeFX1S-10MFX1S-14MFX1S-20MFX1S-30M
      Power supply100-240V AC / 24V DC
      No. of inputs681216
      No. of outputs46814
      Digital outputsRelay / Transistor
      Program cycle period per logical instruction0.55 - 0.7 µs
      User memory2000 steps EEPROM (internal)
      Dimensions in mm (WxHxD)60x90x7560x90x7575x90x75100x90x75


      Jual Mitsubishi Compact PLC Melsec FX2N Seri





























      Mitsubishi Compact PLC Melsec FX2N has set the standards in the industrial automation sector and is one of the biggest-selling controllers worldwide. It has many features normally found in larger controllers like floating-point math, the ability to process 32-bit data words and a wide range of fully-configurable communications options.
      With a processing speed of just 0.08µ s per logical instruction Mitsubishi Compact PLC Melsec FX2N is one of the fastest compact PLC systems available. It has extensive communications capabilities and a wide range of expansion and special function modules are available for configuration of precisely customised systems. 

      Mitsubishi Compact PLC Melsec FX2N series highlights:
      • 16 to 256 inputs and outputs
      • High processing speed ( 0.08µ s per log. instruction)
      • Ample program storage capacity ( 8, 000 steps, expandable to 16, 000 steps) and device ranges
      • Can be expanded with up to eight special-function modules for analog signal processing, temperature data acquisition, communications and positioning applications with up to 16 axes
      • Connection options for Profibus-DP, CC-Link, DeviceNet and AS-Interface
      • User-friendly programming with MS Windows-based programming software package or hand-held programming unit
      • Integrated positioning controller