SEARCH / CARI

Jumat, 12 Juni 2020

PLC OMRON CP2E Reduced development time with function blocks (FBs) programming


Diverse range of functions for your machine

Efficient solution for a flexible production, traceability and monitoring of machine key assets, to respond to operational excellence.
Improved connectivity to networking and serial devices.
Reduced development time with function blocks (FBs) programming.
Battery-free operation increases robustness and reduces maintenance. The extended operating temperature range increase reliability for special applications.







CP2E-N-type/Network model
Number of
points
SpecificationsModel
Power
Supply
InputsOutputsOutput
type
Program
capacity
Data
memory
capacity
Current
consumption
5 VDC24 VDC
CPU Units with
14 points
3777_lu_2_1
100 to
240 VAC
8
points
6
points
Relay10K steps
(FB
capacity:
10K steps)
16K
words
0.15 A0.05 ACP2E-N14DR-A
Transistor
(sinking)
0.21 A0.02 ACP2E-N14DT-A
24 VDCRelay0.15 A0.05 ACP2E-N14DR-D
Transistor
(sinking)
0.21 A0.02 ACP2E-N14DT-D
Transistor
(sourcing)
0.22 A0.02 ACP2E-N14DT1-D
CPU Units with
20 points
3777_lu_2_2
100 to
240 VAC
12
points
8
points
Relay0.17 A0.06 ACP2E-N20DR-A
Transistor
(sinking)
0.27 A0.02 ACP2E-N20DT-A
24 VDCRelay0.17 A0.06 ACP2E-N20DR-D
Transistor
(sinking)
0.27 A0.02 ACP2E-N20DT-D
Transistor
(sourcing)
0.26 A0.02 ACP2E-N20DT1-D
CPU Units with
30 points
3777_lu_2_3
100 to
240 VAC
18
points
12
points
Relay0.41 A0.07 ACP2E-N30DR-A
Transistor
(sinking)
0.52 A0.03 ACP2E-N30DT-A
24 VDCRelay0.37 A0.07 ACP2E-N30DR-D
Transistor
(sinking)
0.51 A0.03 ACP2E-N30DT-D
Transistor
(sourcing)
0.51 A0.03 ACP2E-N30DT1-D
CPU Units with
40 points
3777_lu_2_4
100 to
240 VAC
24
points
16
points
Relay0.39 A0.09 ACP2E-N40DR-A
Transistor
(sinking)
0.59 A0.03 ACP2E-N40DT-A
24 VDCRelay0.39 A0.09 ACP2E-N40DR-D
Transistor
(sinking)
0.59 A0.03 ACP2E-N40DT-D
Transistor
(sourcing)
0.59 A0.03 ACP2E-N40DT1-D
CPU Units with
60 points
3777_lu_2_5
100 to
240 VAC
36
points
24
points
Relay0.44 A0.13 ACP2E-N60DR-A
Transistor
(sinking)
0.71 A0.03 ACP2E-N60DT-A
24 VDCRelay0.41 A0.13 ACP2E-N60DR-D
Transistor
(sinking)
0.71 A0.03 ACP2E-N60DT-D
Transistor
(sourcing)
0.71 A0.03 ACP2E-N60DT1-D

CP2E-S-type/Standard model

Number of
points
SpecificationsModel
Power
Supply
InputsOutputsOutput
type
Program
capacity
Data
memory
capacity
Current
consumption
5 VDC24 VDC
CPU Units with
30 points
3777_lu_3_1
100 to
240 VAC
18
points
12
points
Relay8K steps
(FB
capacity:
8K steps)
8K words0.12 A0.07 ACP2E-S30DR-A
24 VDCTransistor
(sinking)
0.28 A0.02 ACP2E-S30DT-D
Transistor
(sourcing)
CP2E-S30DT1-D
CPU Units with
40 points
3777_lu_3_2
100 to
240 VAC
24
points
16
points
Relay0.13 A0.09 ACP2E-S40DR-A
24 VDCTransistor
(sinking)
0.34 A0.02 ACP2E-S40DT-D
Transistor
(sourcing)
CP2E-S40DT1-D
CPU Units with
60 points
3777_lu_3_3
100 to
240 VAC
36
points
24
points
Relay0.16 A0.13 ACP2E-S60DR-A
24 VDCTransistor
(sinking)
0.48 A0.02 ACP2E-S60DT-D
Transistor
(sourcing)
CP2E-S60DT1-D

CP2E-E-type/Essential model

Number of
points
SpecificationsModel
Power
Supply
InputsOutputsOutput
type
Program
capacity
Data
memory
capacity
Current
consumption
5 VDC24 VDC
CPU Units with
14 points
3777_lu_4_1
100 to
240 VAC
8 points6 pointsRelay4K steps
(FB
capacity:
4K steps)
4K words0.06 A0.04 ACP2E-E14DR-A
CPU Units with
20 points
3777_lu_4_2
12 points8 pointsRelay0.08 A0.06 ACP2E-E20DR-A
CPU Units with
30 points
3777_lu_4_3
18 points12 pointsRelay0.12 A0.07 ACP2E-E30DR-A
CPU Units with
40 points
3777_lu_4_4
24 points16 pointsRelay0.13 A0.09 ACP2E-E40DR-A
CPU Units with
60 points
3777_lu_4_5
36 points24 pointsRelay0.16 A0.13 ACP2E-E60DR-A

Optional Products

Battery

Product nameSpecificationsModel
Battery
3777_lu_5_1
Mounted in an N/S[][]-type CPU Unit.
Mount the Battery when using the clock function.
A Battery cannot be mounted to an E[][]-type CPU Unit.
CP2W-BAT02

Option Board

Product nameSpecificationsCurrent
consumption
Model
5 VDC24 VDC
RS-232C Option
Board
3777_lu_6_1
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an RS-232C port.
Maximum transmission distance: 15 m
0.04 A---CP1W-CIF01
Non-isolated
RS-422A/485
Option Board
3777_lu_6_2
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an RS-422A/485 port.
Maximum transmission distance: 50 m
0.04 A---CP1W-CIF11
Isolated
RS-422A/485
Option Board
3777_lu_6_3
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an RS-422A/485 port.
Maximum transmission distance: 500 m
0.04 A---CP1W-CIF12-V1
RS-232C&RS-232C
Option Board
3777_lu_6_4
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as two RS-232C ports.
Maximum transmission distance: 15 m
0.04 A---CP2W-CIFD1
RS-232C&RS-485
Option Board
3777_lu_6_5
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as one RS-232C port and one isolated
RS-485 port.
Maximum transmission distance:
15 m (RS-232C)
500 m (RS-485)
0.06 A---CP2W-CIFD2
RS-485&RS-485
Option Board
3777_lu_6_6
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as two isolated RS-485 ports.
Maximum transmission distance: 500 m
0.08 A---CP2W-CIFD3
Analog Input Option
Board
3777_lu_6_7
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an analog input module.
• 2 analog inputs
0 to 10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/2000)
0.02 A---CP1W-ADB21
Analog Output
Option Board
3777_lu_6_8
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an analog output module.
• 2 analog outputs
0 to 10 V (Resolution: 1/4000)
0.06 A---CP1W-DAB21V
Analog Input/Output
Option Board
3777_lu_6_9
Mounted in the option slot of an N[][]-type CPU Unit and
can be used as an analog input/output module.
• 2 analog inputs
0 to 10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/2000)
• 2 analog outputs
0 to 10 V (Resolution: 1/4000)
0.08 A---CP1W-MAB221
Note: 1. Maximum one Analog Option Board can be mounted on an N[][]-type CPU Unit.
         2. The CP1W-ME05M Memory Cassette, CP1W-DAM01 LCD Option Board, and CP1W-CIF41 Ethernet Option Board
             cannot be used with the CP2E CPU Unit.
         3. Option Boards cannot be used with the E/S[][]-type CPU Unit.

Expansion I/O Units and Expansion Units (for E30/40/60, S30/40/60, or N30/40/60 CPU Units)

E14/20 or N14/20 CPU Units do not support Expansion I/O Units and Expansion Units.
Unit typeProduct
name
SpecificationsCurrent
consumption
(A)
Model
In-
puts
Out-
puts
Output type5 V24 V
CP1W
Expansion
I/O Units
Input Unit
3777_lu_7_1
8---24 VDC Input0.018---CP1W-8ED
Output Units
3777_lu_7_2
---8Relay0.0260.044CP1W-8ER
Transistor (sinking)0.075---CP1W-8ET
Transistor (sourcing)0.075---CP1W-8ET1
---16Relay0.0420.090CP1W-16ER
Transistor (sinking)0.076---CP1W-16ET
Transistor (sourcing)0.076---CP1W-16ET1
---32Relay0.0490.131CP1W-32ER
Transistor (sinking)0.113---CP1W-32ET
Transistor (sourcing)0.113---CP1W-32ET1
I/O Units
3777_lu_7_3
128Relay0.1030.044CP1W-20EDR1
Transistor (sinking)0.130---CP1W-20EDT
Transistor (sourcing)0.130---CP1W-20EDT1
2416Relay0.0800.090CP1W-40EDR
Transistor (sinking)0.160---CP1W-40EDT
Transistor (sourcing)0.160---CP1W-40EDT1
CP1W
Expansion
Units
Analog Input
Unit
3777_lu_7_4
4CH---Input range: 0 to 5 V,
1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Resolution:
1/6000
0.1000.090CP1W-AD041
Resolution:
1/12000
0.1000.050CP1W-AD042
Analog Output
Unit
3777_lu_7_5
---2CHOutput range:
1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Resolution:
1/6000
0.0400.095CP1W-DA021
---4CHResolution:
1/6000
0.0800.124CP1W-DA041
Resolution:
1/12000
0.0700.160CP1W-DA042
Analog I/O Unit
3777_lu_7_6
4CH4CHInput range: 0 to 5 V,
1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Output range:
1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Resolution:
1/12000
0.1200.170CP1W-MAD44
4CH2CHResolution:
1/12000
0.1200.120CP1W-MAD42
2CH1CHResolution:
1/6000
0.0830.110CP1W-MAD11
Temperature
Sensor Unit
3777_lu_7_7
2CH---Sensor type: Thermocouple (J or K)0.0400.059CP1W-TS001
4CH---Sensor type: Thermocouple (J or K)0.0400.059CP1W-TS002
2CH---Sensor type: Platinum resistance
thermometer (Pt100 or JPt100)
0.0540.073CP1W-TS101
4CH---Sensor type: Platinum resistance
thermometer (Pt100 or JPt100)
0.0540.073CP1W-TS102
4CH---Sensor type:
Thermocouple (J or K)
2channels can be used
as analog input.
Input range: 1 to 5 V, 0 to
10 V, 4-20 mA
Resolution:
1/12000
0.0700.030CP1W-TS003
12CH---Sensor type: Thermocouple (J or K)0.0800.050CP1W-TS004

I/O Connecting Cable

Product nameSpecificationsModel
I/O Connecting Cable80 cm (for CP1W Expansion I/O Units and Expansion Units)
Only one I/O Connecting Cable can be used in each PLC.
CP1W-CN811

Recommended Ethernet Communications Cables

For the Ethernet communications cable specifications, refer to Catalog
ItemRecommended
manufacturer
Cable
length (m)
Model
Wire Gauge and
Number of Pairs:
AWG26, 4-pair Cable
Cable Sheath material:
LSZH *2
Cable with Connectors on
Both Ends (RJ45/RJ45)
Standard RJ45 plug type *1
Cable color: Yellow *3
3777_lu_11_1
OMRON0.3XS6W-6LSZH8SS30CM-Y
0.5XS6W-6LSZH8SS50CM-Y
1XS6W-6LSZH8SS100CM-Y
2XS6W-6LSZH8SS200CM-Y
3XS6W-6LSZH8SS300CM-Y
5XS6W-6LSZH8SS500CM-Y
Wire Gauge and
Number of Pairs:
AWG22, 2-pair cable
Cable with Connectors on
Both Ends (RJ45/RJ45)
Rugged RJ45 plug type *1
Cable color: Light blue
3777_lu_11_2
OMRON0.3XS5W-T421-AMD-K
0.5XS5W-T421-BMD-K
1XS5W-T421-CMD-K
2XS5W-T421-DMD-K
5XS5W-T421-GMD-K
10XS5W-T421-JMD-K
*1. Cables with standard RJ45 plugs are available in the following lengths: 0.2 m, 0.3 m, 0.5 m, 1 m, 1.5 m, 2 m, 3 m, 5 m,
  7.5 m, 10 m, 15 m, 20 m.
  Cables with rugged RJ45 plugs are available in the following lengths: 0.3 m, 0.5 m, 1 m, 2 m, 3 m, 5 m, 10 m, 15 m.
  For details, refer to the Industrial Ethernet Connectors Catalog (Cat. No. G019).
*2. The lineup features Low Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use.
  Although the LSZH cable is single shielded, its communications and noise characteristics meet the standards.
*3. Cable colors are available in yellow, green, and blue.
*4. For details, contact your OMRON representative.

RS-232C Connecting Cable

NameSpecificationsModel
PT-to-PLC
Connecting Cable
Connection cable with programmable terminal NB / NS
For CP2E-N+CP1W-CIF01
Length: 2 mXW2Z-200T
Length: 5 mXW2Z-500T
Connection cable with programmable terminal NB / NS
For CP2E-S/E, CP2E-N+CP2W-CIFD1/CIFD2
Length: 2 mXW2Z-200T-3
Length: 5 mXW2Z-500T-3

DIN Track Accessories

NameSpecificationsModel
DIN TrackLength: 0.5 m; Height: 7.3 mmPFP-50N
Length: 1 m; Height: 7.3 mmPFP-100N
Length: 1 m; Height: 16 mmPFP-100N2
End PlateA stopper to secure the Units on the DIN Track.PFP-M

Programming Devices

Software

Product
name
SpecificationsModel
Number of
licenses
Media
FA Integrated
Tool Package
CX-One Lite
Ver.4.[]
CX-One Lite is a subset of the complete CX-One package
that provides only the Support Software required for micro
PLC applications.
CX-One Lite runs on the following OS.
OS: Windows XP (Service Pack 3 or higher, 32-bit
version) / Windows Vista (32-bit/64-bit version) / Windows
7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit
version) / Windows 8.1 (32-bit/64-bit version) / Windows
10 (32-bit/64-bit version)
CX-One Lite Ver. 4.[] includes Micro PLC Edition
CX-Programmer Ver.9.[].
1 licenseDVDCXONE-LT01D-V4
FA Integrated
Tool Package
CX-One
Package
Ver. 4.[]
CX-One is a comprehensive software package that
integrates Support Software for OMRON PLCs and
components. CX-One runs on the following OS.
OS: Windows XP (Service Pack 3 or higher, 32-bit
version) / Windows Vista (32-bit/64-bit version) / Windows
7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit
version) / Windows 8.1 (32-bit/64-bit version) / Windows
10 (32-bit/64-bit version)
CX-One Ver. 4.[] includes CX-Programmer Ver. 9.[].
1 license
*1
DVDCXONE-AL01D-V4
Note: 1. CP2E CPU Units are supported by CX-One version 4.51 or higher and CX-Programmer version 9.72 or higher.
         2. The CX-One and CX-One Lite cannot be simultaneously installed on the same computer.
         3. For details, refer to the CX-One Catalog (Cat. No. R134).
*1. Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.

Kamis, 11 Juni 2020

Jual Mitsubishi QJ61BT11N




QJ61BT11N
MELSEC-Q Series CC-Link Master/Local Module QJ61BT11N

Feature
These modules are available as master or local stations for CC-Link
CC-Link parameters can be set on the Parameter Setting screen of the programming software GX Works 2 for MELSEC
Setting a standby master station can maintain a data link even if there is something wrong with the regular master station. Additionally, a redundant function enables the master station to return to the system even during data link control at the standby master station in anticipation of the breakdown of the standby master station
High-speed communication is available in remote I/O network mode only when slave stations are remote I/O stations (Parameter setting is not required either)

Selasa, 09 Juni 2020

Jual Inverter Delta B Series , Inverter Delta C Series, Inverter Delta CP Series, Inverter Delta C2000 Series,Inverter Delta E Series,Inverter Delta EL Series, Inverter Delta M Series, Inverter Delta S Series , Inverter Delta L Series, Inverter Delta VE Series


Inverter Delta 7.5kw 3phase 380volt 10hp VFD075B43A Delta B Series
Inverter Delta 2.2kw 1phase 210volt 3hp VFD022B21A Delta B Series
Inverter Delta 1.5kw 1phase 210volt 2hp VFD015B21A Delta B Series
Inverter Delta 0.75kw 1phase 210volt 1hp VFD007B21A Delta B Series
Inverter Delta 0.75kw 3Phase 380volt 1hp VFD007B43A Delta B Series
Inverter Delta 1.5kw 3phase 380volt 2hp VFD015B43A Delta B Series
Inverter Delta 2.2kw 3phase 380volt VFD022B43B Delta B Series


Inverter Delta 37kw 380volt 3phase 40hp VFD370C43S Delta C Series
Inverter Delta 22kw 3phase 380volt 25hp VFD220C43A Delta C Series
Inverter Delta 15kw 3phase 380volt 20hp VFD150C43A Delta C Series
Inverter Delta 0.75kw 3phase 380-volt 1hp VFD007C43A Delta C Series
Inverter Delta 45kw 3phase 380volt 50hp VFD450C43S Delta C Series


Inverter Delta 15kw 3phase 380volt 20hp VFD150CP43B-21 Delta CP Series
Inverter Delta 11kw 3phase 380volt 15hp VFD110C43A Delta C2000 Series
Inverter Delta 2.2kw 3phase 380volt 3hp VFD022C43A Delta C2000 Series



Inverter Delta 0.75kw 3phase 380volt 1hp VFD007E43T Delta E Series
Inverter Delta 0.75kw 3phase 380volt 1hp VFD007E43A Delta E Series
Inverter Delta 7.5kw 3phase 380volt 10hp VFD075E43A Delta E Series
Inverter Delta 1.5kw 3phase 3phase 2hp VFD015E43T Delta E Series
Inverter Delta 0.75kw 1phase 210volt 1hp VFD007E21T Delta E Series
Inverter Delta 0.75kw 1phase 210volt 1hp VFD007E21A Delta E Series


Inverter Delta 1.5kw 1phase 210volt 2hp VFD015EL21A Delta EL Series
Inverter Delta 2.2kw 1phase 210volt 3hp VFD022EL21A Delta EL Series
Inverter Delta 1.5kw 3phase 380volt 2hp VFD015EL43A Delta EL Series
Inverter Delta 0.75kw 1phase 210volt 1hp VFD007EL21A Delta EL Series
Inverter Delta 3.7kw 3phase 380volt 5hp VFD037EL43A Delta EL Series
Inverter Delta 0.75kw 3phase 380volt 1hp VFD007EL43A Delta EL Series
Inverter Delta 2.2kw 3phase 380volt 3hp VFD022EL43A Delta EL Series



Inverter Delta 0.75kw 1phase 210volt 1hp VFD007M21A Delta M Series
Inverter Delta 1.5kw 1phase 210volt 2hp VFD015M21A Delta M Series
Inverter Delta 0.75kw 3phase 380volt 1hp VFD007M43B Delta M Series
Inverter Delta 1.5kw 3phase 380volt 2hp VFD015M43B Delta M Series
Inverter Delta 7.5kw 3phase 380volt 10hp VFD075M43A Delta M Series
Inverter Delta 2.2kw 1phase 210volt 3hp VFD022M21A Delta M Series
Inverter Delta 2.2kw 3phase 380volt 3hp VFD022M43B Delta M Series
Inverter Delta 3.7kw 3phase 380volt 5hp VFD037M43A Delta M Series


Inverter Delta 0.4kw 1phase 210volt 0.5hp VFD004S21A Delta S Series
Inverter Delta 0.75kw 3phase 380volt 1hp VFD007S43A Delta S Series


Inverter Delta 0.75kw 1phase 210volt 1hp VFD007L21A Delta L Series
Inverter Delta 0.4kw 1phase 210volt 0.5hp VFD004L21A Delta L Series
Inverter Delta 100Watt 1phase 210volt 0.125hp VFD001L21A Delta L Series
Inverter Delta 200Watt 1phase 210volt 0.25hp VFD002L21W-I Delta L Series


Inverter Delta 18,5kw 3phase 380volt 25hp VFD185V43A-2 Delta VE Series