SEARCH / CARI

Kamis, 30 Januari 2020

Jual SURGE PROTECTION DEVICE SHIHLIN


BHP20-1P / BHP20-PNR / BHP20-PR / BHP20-PNR / BHP40-PR / BHP40-PNR / BHP40-P BHP40-PNR

Max. discharge current Imax/Iimp: 20kA (8/20μs)

Features
  • Standards: IEC61643, IEC61312-1, 61643-1, 61000-5-6, VED0675,UL14492-2,UL1283,CSA22.2
  • Modular design, anti-error assembling design, withdraw able surge arrestor allow quick replacement of the failed module (end of life) without cutting the power.
  • With standard DIN rail (35mm) installation, easy to install and speed up the replacing process.
  • The IP code dustproof and waterproof level is IP20.
  • Meets the IEC 61643-11 standard and CE declaration.
  • Voltage impulse counter (AC110V/220V) is available for monitoring maximum of 99 counts.
  • Has memory function, non-return to zero after power failure.
Specification
  • Din rail installation
  • Class II
  • Max. discharge current Imax/Iimp: 20kA (8/20μs)
  • Pole: 1P / 1P+1 / 1P+N / 3P / 3P+1 / 3P+N
  • Uc(AC): 320V
  • In(8/20μs): 10kA

Jual RESIDUAL CURRENT CIRCUIT BREAKER (RCBO) SHIHLIN


BHL-31C / BHL-32C / BHL-33C / BHL-34C

RCBO = Fungsi MCB + Fungsi RCCB

Rated Current: 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63A

Features
  • Excellent anti-electromagnetic interference capability which avoid the faulty trip caused by a transient over-voltage.
  • Tripping indication:Red- indicates earth-leakage tripped; white- no earth-leakage tripping.
  • Test button(yellow) provides earth-leakage testing function during the regular maintenance.
  • Unique installation design, tool-free installation is realized.
  • Tripping characteristics:
  • C type: 5~10In
  • D type:10~15In
Specification
  • Standard: IEC61009
  • Rated Current: 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63A
  • Rated sensitivity current:30mA
  • Pole: 1P+N, 2P, 3P, 4P

Jual MOLDED CASE CIRCUIT BREAKER (MCCB) SHIHLIN


MCCB ECONOMY SERIES

  • BM30-CN
  • BM50-CN
  • BM100-MN
  • BM250-CN
  • BM400-CN
  • BM630-CN
  • BM800-CN


MCCB STANDARD SERIES

  • BM30-SN
  • BM60-SN
  • BM100-SN
  • BM125-SN
  • BM250-SN
  • BM400-SN
  • BM630-SN
  • BM800-SN


MCCB HIGH CAPACITY SERIES

  • BM60-HN
  • BM100-HN
  • BM100-HBN
  • BM125-HN
  • BM250-HN
  • BM400-HN
  • BM400-RN
  • BM630-HN
  • BM630-RN
  • BM800-HN
  • BM800-RN


MCCB HIGH CAPACITY SERIES

  • BM100-H
  • BM100-HC
  • BM100-HS
  • BM250-HB
  • BM250-HC
  • BM250-HS
  • BM1000-HS
  • BM1200-HS
  • BM1600-HS


ELECTRONIC MCCB

  • BM100-HE
  • BM100-RE
  • BM100-UE
  • BM250-HE
  • BM250-RE
  • BM250-UE
  • BM400-HE
  • BM400-RE
  • BM400-UE
  • BM630-HE
  • BM630-RE
  • BM630-UE
  • BM800-SE
  • BM800-RE
  • BM800-UE
  • BM1000-SE
  • BM1000-HE
  • BM1250-SE
  • BM1250-HE

Jual MINIATURE CIRCUIT BREAKER (MCB) SHIHLIN

BHA Series (6kA)

Features
  • Provide circuit protections: Good choice for overload and short-circuit protections.
  • Easy installation: Modularized structure design can be tool-free installed on standard DIN-rail TH35mm.
  • Tripping characteristics:
  • C type: 5~10In
Specification
  • Standard: IEC60947-2, IEC60898, GB10963
  • Rated Current: 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
  • Pole: AC: 1P, 2P, 3P, 4P / DC: 1P, 2P

Model:
  • BHA-31C 1P, Pilihan arus nominal: 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
  • BHA-32C 2P, Pilihan arus nominal: 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
  • BHA-33C 3P, Pilihan arus nominal: 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
  • BHA-34C 4P, Pilihan arus nominal: 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A

MCB ACCESSORIES



Alarm Switch, Axuiliary Contact, Shunt Trip, Under Voltage Trip, Over Voltage Trip

Features
  • Tool-free, left-mounted on the MCBs.
  • Maximum three (3) accessories can be installed on one MCB.
  • Maximum two (2) auxiliary switch (AX) can be installed for one MCB.

Specification
  • BHK1: Alarm Switch (AL) - 1NO 1NC // 230V 6A, 440V 3A
  • BHK2: Auxiliary Contact (AX) - 1NO 1NC // 230V 6A, 440V 3A
  • BHK3: Shunt Trip (SHT) - 1NO 1NC // 230V 6A, 440V 3A // AC12V/24~48V/230~415V, DC12V/12~48V/110~130V
  • BHK4: Under Voltage Trip (UVT) - 1NO 1NC // 230V 6A, 440V 3A // AC220~240V, DC48V
  • BHK5: Over Voltage Trip (OVT) - Rated voltage 230V // 15mA // over voltage range 280V +-5% // trip time 0.25ms

Jual ELCB (EARTH LEAKAGE CIRCUIT BREAKER with Overload Function) SHIHLIN ELECTRIC

1. BL50-SN


Rated current: 15, 20, 30, 40, 50A

Specification
  • Hydraulic magnetic
  • Standard: IEC60947-2
  • Rated current: 15, 20, 30, 40, 50A
  • Rated current sensitivity: 30 / 100 / 300 / 500mA (high speed) ; 100 - 300 - 500mA
  • Pole: 3P / 4P
  • Operating time: 0.04s (high speed) ; 0.1 - 0.4 - 0.8 - 2.0s
2. BL100-SN


Rated current: 15, 20, 30, 40, 50, 60, 75, 100A

Specification
  • Hydraulic magnetic
  • Standard: IEC60947-2
  • Rated current: 15, 20, 30, 40, 50, 60, 75, 100A
  • Rated current sensitivity: 30 / 100 / 300 / 500mA (high speed) ; 100 - 300 - 500mA
  • Pole: 3P / 4P
  • Operating time: 0.04s (high speed) ; 0.1 - 0.4 - 0.8 - 2.0s
3. BL250-SN


Rated current: 175, 200, 225, 250A

Specification
  • Adj. thermal / Fixed magnetic
  • Standard: IEC60947-2
  • Rated current: 175, 200, 225, 250A
  • Rated current sensitivity: 30 - 100 - 500mA (high speed) ; 100 - 300 - 500mA
  • Pole: 3P / 4P
  • Operating time: 0.04s (high speed) ; 0.1 - 0.4 - 0.8 - 2.0s

4. BL400-SN


Rated current: 250, 300, 350, 400A

Specification
  • Thermal magnetic
  • Standard: IEC60947-2
  • Rated current: 250, 300, 350, 400A
  • Rated current sensitivity: 30 - 100 - 500mA (high speed) ; 100 - 300 - 500mA
  • Pole: 3P / 4P
  • Operating time: 0.04s (high speed) ; 0.1 - 0.4 - 0.8 - 2.0s
5. BL630-HN

Rated current: 500, 630A

Specification
  • Fixed thermal / Adj. magnetic
  • Standard: IEC60947-2
  • Rated current: 500, 630A
  • Rated current sensitivity: 30 - 100 - 500mA (high speed) ; 100 - 300 - 500mA
  • Pole: 3P / 4P
  • Operating time: 0.04s (high speed) ; 0.1 - 0.4 - 0.8 - 2.0s

6. BL800-SN

Rated current: 700, 800A

Specification
  • Fixed thermal / Adj. magnetic
  • Standard: IEC60947-2
  • Rated current: 700, 800A
  • Rated current sensitivity: 30 - 100 - 500mA (high speed) ; 100 - 300 - 500mA
  • Pole: 3P / 4P
  • Operating time: 0.04s (high speed) ; 0.1 - 0.4 - 0.8 - 2.0s

Jual EARTH LEAKAGE BREAKER (ELCB) SHIHLIN ELECTRIC

1. ELCB (Earth Leakage Breaker)


  • BL-KF


  • BL-K30F 380V



Jual BREAKER ACCESSORIES SHIHLIN ELECTRIC

1. Alarm Switch Module

- AL-BM100100SNL
- AL-BM100HNL
- AL-BM250SNL
- AL-BM250HBL
- AL-BM400HNL
- AL-1600HSL

2. Auxiliary Contact Module

- AUX-BM100SNL
- AUX-BM100HNL
- AUX-BM250SNL
- AUX-BM100HL
- AUX-BM400HNL
- AUX-BM1000HSL

3. External Handel

- EH100N
- EH125N
- EH250N
- EH250H
- EH400N
- EH800N

4. Manual Handel

- MA100N
- MA125N
- MA250N
- MA250H
- MA400N
- MA800N

Specification
  • MA-100N: 3P / 4P -- BM30-SN, BM50-CN, BM60-SN/HN, BM100-SN/MN, BL50-SN
  • MA-125N: 3P / 4P -- BM60HBN, BM100-HN, BM125-SN/HN, BL100-SN/HN
  • MA-250N: 3P / 4P -- BM100-HBN, BM160-SN/HN, BM250-SN/HN, BL160-SN, BL250-SN
  • MA-400N: 3P / 4P -- BM400-SN/HN/RN/UN, BL400-SN/HN/RN/UN
  • MA-800N: 3P / 4P -- BM630-SN/HN/RN/UN, BM800-CN/SN/HN/RN, BL630-HN/RN/UN, BL800-SN/HN/RN
5. Elektrik Handel

-MT100N
-MT125N
-MT250N
-MT250E
-MT400N
-MT800N

Features
  • Applicable Voltage: DC 24V, AC 110V / DC 110V, AC 230V / DC 220V

Specification
  • MT-100N: 3P / 4P -- BM30-SN, BM50-CN, BM60-SN/HN, BM100-SN/MN, BL50-SN
  • MT-125N: 3P / 4P -- BM60HBN, BM100-HN, BM125-SN/HN, BL100-SN/HN
  • MT-250N: 3P / 4P -- BM100-HBN, BM160-SN/HN, BM250-SN/HN, BL160-SN, BL250-SN
  • MT-400N: 3P / 4P -- BM400-SN/HN/RN/UN, BL400-SN/HN/RN/UN
  • MT-800N: 3P / 4P -- BM630-SN/HN/RN/UN, BM800-CN/SN/HN/RN, BL630-HN/RN/UN, BL800-SN/HN/RN
  • MT-250E: 3P / 4P -- BM100-H/HC/HS, BM160-HB/HC/HS, BM250-HB/HC/HS

6. Shunt Trip Module


Features
  • Applicable Voltage: DC 24V/48V, AC 110-220V, AC 220-440V

- SHT-BM100SNR
- SHT-BM100HNR
- SHT-BM250SN
- SHT-BM250HBR
- SHT-BM400HN
- SHT-BM1000HSR

7. Under Voltage Trip Module

- UVT-BM100SNR
- UVT-BM100HNR
- UVT-BM250SNR
- UVT-BM400SN
- UVT-BM1600HSR