SEARCH / CARI

Senin, 31 Juli 2017

CJ2M CPU Units (Built-in EtherNet/IP) : CJ2M-CPU35, CJ2M-CPU34,CJ2M-CPU33,CJ2M-CPU32,CJ2M-CPU31


- CJ2M (Built-in EtherNet/IP) CPU Units, I/O capacity Mountable Units (Expansion Racks) 2,560 points/40 Units (3 Expansion Racks max), Program capacity 60K steps, Data Memory capacity 160K words (DM 32K words) EM 32K words x 4 banks), LD instruction Execution time 0,04 us, EtherNet/IP function YES, Option board slot YES, Current Consumption (A) 5 V 0,7 *    : CJ2M-CPU35
- CJ2M (Built-in EtherNet/IP) CPU Units, I/O Capacity Mountable Units (Expansion Racks) 2,560 points/40 Units (3 Expansion Racks max), Program capacity 30K steps, Data Memory capacity 160K words (DM 32K words EM 32K words x 4 banks) LD instruction Execution time 0,04 us , EtherNet/IP function YES, Option board slot YES, Current Consumption (A) 5 V  0,7 *   :  CJ2M-CPU34
- CJ2M (Built-in EtherNet/IP), I/O Capacity Mountable Units (Expansion Racks0 2,560 Points/40 Units (3 Expansion Racks max), Program Capacity 20K steps, Data Memory capacity 64K words (DM 32K words EM 32K words x 1 bank), LD instruction Execution time 0,04 us, EtherNet/IP YES, Option board YES, Current Consumption (A) 5 V 0,07 *  :  CJ2M-CPU33
- CJ2M (Built-in EtherNet?IP) CPU Units, I/O capacity Mountable Units (Expansion Racks) 2,560 points/40 units (3 Expansion Racks max), Program capacity  10K steps, Data Memory capacity64K words (DM 32K words em 32k words x 1 bank), LD instruction execution time 0,04 us, EtherNet/IP function YES, Option board slot YES, Current Consumption (A) 5 V 0,7  * : CJ2M-CPU32
- CJ2M (Built-in) CPU Units, I/O Capacity Mountable Units (Expansion Racks) 2,560 points/40 Units (ExpansionRacks max), LD instruction execution time 0,04 us, EtherNet/IP function YES, Option board slot YES, Current Consumption (A) 5 V 0,7 *   : CJ2M-CPU31

CJ1W-IC / II CJ-series I/O Control Unit / I/O Interface Unit


- CJ-series I/O Control Unit, Specifications Mount one I/O Control on the CPU Rack when connecting on or more Expansion Racks Connecting Cable CS1W-CN[][]3 Expansion Connecting Cable Connected Unit CJ1W-II101 I/O Interface Unit Mount to the right of the CPU Unit, Current Consumption (A) 5 V 0,02  : CJ1W-IC101

Kamis, 27 Juli 2017

CJ1W-NC[]71 CJ-series Position Control Unit with MECHATROLINK-II interface: CJ1W-NC271,CJ1W-NC471,CJ1W-NCF71, CJ1W-NCF71-MA


- CJ1 CPU Bus Units, Position Control Unit with MECHATROLINK-II interface, Control output interface Control commands executed by MECHATROLINK-II synchronous communications Direct operation by ladder programming Control mode Position control speed control or torque control, No of axes 2, N of unit numbers allocated 1, Current Consumption (A) 5 V  0.36  : CJ1W-NC271
- CJ1 CPU Bus Units, Position Control Unit with MECHATROLINK-II interface, Control output interface Control commands executed by MECHATROLINK-II synchronous communications Direct operation by ladder programming Control mode Position control speed Control or torque control, No of axes 4 axes, No of unit numbers allocated 1, Current Consumption (A) 5 V 0,36  : CJ1W-NC471
- CJ1 CPU Bus Units, Position Control Unit with MECHATROLNK-II synchronous communications Direct operation by ladder programming Control mode  position control speed control or torque control, No of axes 16 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0,36  : CJ1W-NCF71
- CJ1 CPU Bus Units, Position Control Unit MECHATROLINK-II interface, Control output interface Control commands MECHATROLINK-II synchronous communications Direct Operation by ladder Programming Control mode position control or torque control, No of axes 16, No of units  numbers allocated 1, Current consumption (A) 5 V  0,36  : CJ1W-NCF71-MA

CJ1W-SPU01-V2 CJ-series High-speed Data Storage Unit (SPU Unit)


- CJ1 CPU Bus Units, SPU Unit (High speed Data storage Unit) PC Card slot CF Card Type I/II x 1 slot Use an OMRON HMCEF   Memory card, Ether (LAN) port 1 port (10/100Base-TX), No of unit Numbers allocated 1, Current consumption (A) 5 V 0.56  : CJ1W-SPU01-V2

CJ1W-EIP21 CJ-series EtherNet/IP Unit


- CJ1 CPU Bus Units, EtherNet/IP Unit, Communications functions shielded twisted-pair (STP) cable categories, Communications Functions Tag Data link Functions Message Communications Functions, Units per CPU Unit 8 max *1 , No of unit numbers allocated 1, Current consumption (A) 5 V 0.41 : CJ1W-EIP21 *2

CJ1W-NC[]81 / []82 CJ-series Position Control Units with EtherCAT interface: CJ1W-NC281,CJ1W-NC481,CJ1W-NC881,CJ1W-NCF81,CJ1W-NC482,CJ1W-NC882,CJ1W-NCF82


- CJ1 CPU Bus Units, Position Control Units with Ether Cat interface, Control output interface control commands executed by EtherCAT Communications positioning function Memory operation Direct operation by ladder programming, No of axes 2 axes, No unit numbers allocated 1, Current Consumption (A) 5 V 0.46   : CJ1W-NC281
- CJ1 CPU Bus Unit, Position Control Units with Ether CAT interface, Control output interface Control commands executed by EtherCAT communications positioning Function Memory operation Direct Operation by ladder Programming, No of axes 4 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0.46  : CJ1W-NC481
- CJ1 CPU Bus Unit, Position Control Units with EtherCAT interface, Control output interface Control commands  executed by EtherCAT communications positioning Functions Memory operation Direct operation by ladder programming, No of axes 8 axes, No f unit numbers allocated 1, Current Consumption (A) 5 V 0.46  : CJ1W-NC881
- CJ1 CPU Bus Units, Position Control Units with EtherCAT interface, Control output interface Control commands executed EtherCAT communications positioning function Memory operation Direct operation by ladder programming, No of axes 16 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0,46   : CJ1W-NCF81
- CJ1 CPU Bus Unit, Position Control Units with EtherCAT interface, Control output interface Control commands executed by EtherCAT communications Positioning function Memory operation Direct operation by ladder programming I/O communications 64 nodes, No of axes 4 axes, No of unit numbers allocated 1, Current Consumption (A) 5 V  0,46  : CJ1W-NC482
- CJ1 CPU Bus Units , Position Control Units with EtherCAT interface, Control output interface Control commands executed by EtherCAT communications Positioning function Memory operation Direct operation by ladder programming I/O communications 64 nodes, No of axes 8 axes, No of unit numbers allocated 1, Current Consumption (A) 5 V 0.46  : CJ1W-NC882
- CJ1 CPU Bus Units, Position Control units with EtherCAT interface, Control output interface Control commands executed by EtherCAT positioning function Memory operation Direct operation by ladder programmingI/O communication 64 nodes, No of axes 16 axes, No of unit numbers allocated 1, Current consumption (A) 5 V 0.46  : CJ1W-NCF82

CJ1W-ECT21 CJ-series EtherCAT® Slave Unit


- CJ1 CPU Bus Unit, Ether Cat Slave Unit, Communications cable STP (shielded twisted-pair) cable of category 5 or higher with double shielding,Comunications Functions Refreshing methods Free-Run Mode PDO data sizes TxPDO 400byte max/ RxPDO 400 byte max, No of Unit numbers allocated 1, Current consumption (A) 5 V 0.34  : CJ1W-ECT21*